Resolved Issues in ExtremeXOS 31.4

The following issues were resolved in ExtremeXOS 31.4. ExtremeXOS 31.4 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, and 31.3. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 31.4
Defect Number Description
General
EXOS-19822 The following error message occurs with an IPFIX configuration:

tIpfixSD: Unable to map hardware port to slot:port, modid=0, port=0

EXOS-28203 Netlogin authentication fails when VLAN is statically created, but a dynamic VLAN creation request is received from the RADIUS accept packet.
EXOS-28695 After configuring the NSI by RestConf, the RestConf breaks.
EXOS-28799 If the STP domain is renamed, then the change is not reflected in the show configuration output.
EXOS-28962 The Syscontact and SysLocation values cannot be negated once configured.
EXOS-29103 The default timezone configuration is not present in the "show configuration detail" command, resulting in the inability to revert any timezone configuration to its default value.
EXOS-29189 cliMaster process consumes high CPU after disabling BFD and terminating the SSH session running BFD statistics.
EXOS-29257 openconfig-platform:components does not fetch the transceiver information of all ports.
EXOS-29300 IPv6 Neighbor discovery fails intermittently on MLAG peer.
EXOS-29337 Traffic destined to the subnet IP is broadcast on all the ports present in the destination VLAN.
EXOS-29466 The switch doesn't skip over the lines starting with "#" in the .lst files.
EXOS-29485 If nodealias and netlogin are enabled on the same port, then the nodealias entry will not be created for a client unless the client sends a packet destined for the switch CPU.
ExtremeSwitching X440-G2 Series Switches
EXOS-28728 When adding node in a stack, a nodealias process signal 11 crash occurs.
ExtremeSwitching X590 Series Switches
EXOS-28772 Default route shows unfeasible after an IBGP adjacency flap of a peer switch when multipath is configured.
ExtremeSwitching X460-G2 Series Switches
EXOS-6335 MPLS exp replacement is not working on the transit VPLS node.
ExtremeSwitching X690 Series Switches
EXOS-29436 L3VPN routes are not installed if VPN VRF is configured after BGP neighbor.
ExtremeSwitching X465 Series Switches
EXOS-25912 For ExtremeSwitching X465 series switches with VIM5-4YE-1 modules, high convergence times occur for EAPS, ERPS, and BFD features.
ExtremeSwitching X695 Series Switches
EXOS-29312 When optics.xmod is installed on an ExtremeSwitching X695 series switch, an error message is displayed due to a missing file.
BGP
EXOS-24674 Disabling BGP export-policy in VPN VRF is not getting reflected in the show configuration command.
ExtremeCloud IQ
EXOS-29535 After disabling IQ Agent, the switch is continuously trying to establish a connection with ExtremeCloud IQ when it is not reachable.
Extended Edge Switching
EXOS-28969 VPEX rings are stuck in 'Formation-disabled' after rebooting BPEs.
EXOS-29108 VPEX ring is not detected due to missing ECID in extended slot after a reboot of the Controlling Bridge.
EXOS-29435 VPEX ring stuck in Severed state after BPE reboot due to LACP aggregation failure on a cascade port.
Fabric Attach
EXOS-26355 In Fabric Attach, rebooting one MLAG peer causes a loss of management to another MLAG peer.
EXOS-28354 Fabric Attach assignments learned from netlogin FA clients are not checkpointed to the MLAG peer switch.
SNMP
EXOS-29149 Incorrect Tx/Rx power threshold values are returned when the "Extreme Enterasys entity sensor MIB" is polled.
SummitStack
EXOS-29286 ICMP packets are not egressing after failover.
Universal Hardware
EXOS-29590 The following error is observed when attempting a NOS persona change: Error: Failed to download image - Unable to extract validate.txt from VOSS package.
VLAN
EXOS-29362 A VxLAN error message is seen and port is not added to the hardware table.