This release incorporates all fixes from prior releases, up to and including the following releases:
Issue number |
Description |
---|---|
CFD-10229 | Dropping ARP reply packet destined for its peer when ingressing in different VLAN and needs to be bridged out to the destined VLAN |
CFD-10804 |
Only 5320-48P-8XE and 5320-48T-8XE support more than one VRF with IP configuration (either GRT or user-created). Because of this restriction, Auto-sense cannot create the automatic SD-WAN VRF configuration for the 16- or 24-port models if an IP configuration already exists. |
CFD-10917 | FDB entries not flushed when TCN received on a ring port |
CFD-11001 | A static S-UNI cannot be added to an I-SID mapped to a dynamic VLAN |
CFD-11062 | Error in the console Error parsing '/intflash/khi/khi_boot_count'!. |
CFD-11178 | The show sys-info fan command displays information intermittently. |
CFD-11280 | VSP 7400 Series: Extreme Optics reporting 70+°C and Fan speed remains low. |
VOSS-29220 |
In a scaled Multi-area SPB topology, after an event like an NNI link down, the fail over time for multicast traffic can take up to 23-25 seconds when using 5720 Series switches as the boundary node pair. |