The following issues were resolved in Switch Engine 32.3. Version 32.3 includes all fixes up to and including versions 31.6, 31.7, 32.1, and 32.2.
Defect Number | Description |
---|---|
General | |
EXOS-30265 | SNMP query on pethPsePortIndex is returning both slot and port information instead of just the port value. |
EXOS-31801 | Error messages are logged after an upgrade or switch rescue. |
EXOS-31968 | The outer tag was removed when sending LLDP frames over L2PT. |
EXOS-32032 | Incorrect values are returned for Tx and Rx power sensor states when polled via SNMP. |
EXOS-32042 | The error message "Failed to set port dot1p 8" is displayed in the log. |
EXOS-32120 | The operating system sends a double authentication request for the same client on ab LLDP-enabled port. |
EXOS-32187 | Edge-Safeguard blocked an MLAG port when the MLAG device reboots, with no signs of a loop. |
EXOS-32222 | ExtremeCloud IQ ‑ Site Engine raises an alarm if a file named EXTRTEST exists with the TFTP server. |
EXOS-32264 | ARP packets are not sent via the Standby slot when starting the stack with ports disabled. |
EXOS-32327 | SLPP Guard not disabling the ports if CPU congestion is present. |
EXOS-32538 | ACL process crash occurs when adding an L2PT profile in VPLS. |
EXOS-32580 | HAL signal 11 crash occurs. |
EXOS-32603 | Netlogin web-based URL redirection doesn't work when HTTP is disabled and HTTPS is enabled. |
EXOS-32614 | The IP address is reversed in the SNMP response message. |
EXOS-32776 | Switch unresponsive after upgrading from 30.7.1.1patch1-103 to 31.7.1.4 patch1-36 with ONEPolicy configured. |
EXOS-32959 | Transceiver RxPower values are displayed incorrectly in switch logs. |
ExtremeSwitching 5420 Series Switches | |
EXOS-32117 | The "Image integrity check" field in the show switch management command output is set to "Unknown". |