This procedure checks whether network continuity might be the reason for dropped packets.
device# ping 10.24.81.2 PING 10.24.81.2 (10.24.81.2): 56 octets data 64 octets from 10.24.81.2: icmp_seq=0 ttl=128 time=9.4 ms 64 octets from 10.24.81.2: icmp_seq=1 ttl=128 time=0.3 ms 64 octets from 10.24.81.2: icmp_seq=2 ttl=128 time=0.3 ms 64 octets from 10.24.81.2: icmp_seq=3 ttl=128 time=0.3 ms 64 octets from 10.24.81.2: icmp_seq=4 ttl=128 time=0.3 ms --- 10.24.81.2 ping statistics --- 5 packets transmitted, 5 packets received, 0% packet loss round-trip min/avg/max = 0.3/2.1/9.4 ms
device# show interface eth 0/1 Ethernet 0/1 is admin down, line protocol is down (admin down) Hardware is Ethernet, address is 0000.aaaa.bbbb Current address is 0000.aaaa.bbbb Pluggable media present Interface index (ifindex) is 203431936 (0xc202000) MTU 1548 bytes 10G Interface LineSpeed Actual : Nil LineSpeed Configured : Auto, Duplex: Full Priority Tag disable Forward LACP PDU: Disable Route Only: Disabled Tag-type: 0x8100 Last clearing of show interface counters: 11:18:42 Queueing strategy: fifo Receive Statistics: 0 packets, 0 bytes Unicasts: 0, Multicasts: 0, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: 0, Over 127-byte pkts: 0 Over 255-byte pkts: 0, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(Jumbo): 0 Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: 0 packets, 0 bytes Unicasts: 0, Multicasts: 0, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0 Rate info: Input 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate Route-Only Packets Dropped: 0 Time since last interface status change: 11:18:42
device# show media interface ethernet 0/1 Interface Ethernet 0/1 Identifier 3 SFP Connector 7 LC Transceiver 0000000000000010 10_GB/s Name sw Encoding 6 Baud Rate 103 (units 100 megabaud) Length 9u 0 (units km) Length 9u 0 (units 100 meters) Length 50u 8 (units 10 meters) Length 62.5u 3 (units 10 meters) Length Cu 0 (units 1 meter) Vendor Name BROCADE Vendor OUI 00:05:1e Vendor PN 57-0000075-01 (10GE SR SFP+) Vendor Rev A Wavelength 850 (units nm) Options 001a BR Max 0 BR Min 0 Serial No AAF313060000MV6 Date Code 130206 Optical Monitor Yes Temperature 20 Centigrade Voltage 3286.2 (mVolts) Current 0.278 (mAmps) TX Power 13.3 (uWatts) / -18.761 (dBm) RX Power 2.7 (uWatts)
Note
Some devices do not display TX Power.The new MAC address should appear here.
If the output does not show all neighbors, contact your device support provider.
Enter this command on other network devices to ensure that those devices can detect this MAC address.