Optical lane monitoring table

The following table displays the optical parameters table for Temperature, Tx Power, Rx Power, and Tx Bias Current values and the status for all lanes within a 40G Optic of type SR4 and LR4, 100G optic of type LR4 and LR10. LR4 and SR4 have 4 lanes per optic, LR10 has 10 lanes per optic.

Objects and OID Access Description

bcsiOptMonLaneTable

1.3.6.1.4.1.1588.3.1.8.1.1

None

This table lists the instrumented parameters of all lanes within a 40 G optic of type SR4 and LR4, 100G optic of type LR4 and LR10. LR4 and SR4 have 4 lanes per optic and LR10 has 10 lanes per optic.

bcsiOptMonLaneEntry

1.3.6.1.4.1.1588.3.1.8.1.1.1

None

Only the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table.

bcsiOptMonLaneNum

1.3.6.1.4.1.1588.3.1.8.1.1.1.1

Syntax: Unsigned32

None

This object is the lane number of the 40G and 100G optic. LR4 and SR4 have 4 lanes per optic and LR10 has 10 lanes per optic.

bcsiOptMonLaneTemperature

1.3.6.1.4.1.1588.3.1.8.1.1.1.2

Syntax: SnmpAdminString

Read-only

This object holds the value of the transmitter laser diode temperature for the lane in the interface. Indicates the health of the transmitter.

The format is xxx.yyyy C (Celsius), followed by whether the measured value is normal, high/low alarm, or high/low warning.

bcsiOptMonLaneTxPowerStatus

1.3.6.1.4.1.1588.3.1.8.1.1.1.3

Syntax: Integer

Read-only

This object holds the value of the transmitter optical signal power for the lane in the interface, measured in decibel-milliwatts (dBm), followed by whether this is a this is a normal value, or high or low warning or alarm.

bcsiOptMonLaneTxPowerStatus is one of the following status:
  • notSupported (1)
  • notApplicable (2)
  • highAlarm (3)
  • highWarn (4)
  • normal (5)
  • lowWarn (6)
  • lowAlarm (7)

bcsiOptMonLaneTxPower

1.3.6.1.4.1.1588.3.1.8.1.1.1.4

Syntax: SnmpAdminString

Read-only

This object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.

bcsiOptMonLaneTxPowerVal

1.3.6.1.4.1.1588.3.1.8.1.1.1.5

Syntax: Unsigned32

Read-only

The value of the transmitter optical signal power for the lane in the interface, measured in microwatt.

bcsiOptMonLaneRxPowerStatus

1.3.6.1.4.1.1588.3.1.8.1.1.1.6

Syntax: Integer

Read-only

The status of the receiver optical signal power for the lane in the interface, indicating whether this is normal or an alarm is present.

bcsiOptMonLaneTxPowerStatus is one of the following status:
  • notSupported (1)
  • notApplicable (2)
  • highAlarm (3)
  • highWarn (4)
  • normal (5)
  • lowWarn (6)
  • lowAlarm (7)

bcsiOptMonLaneRxPower

1.3.6.1.4.1.1588.3.1.8.1.1.1.7

Syntax: SnmpAdminString

Read-only

The value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, high/low warning, or an alarm.

bcsiOptMonLaneRxPowerVal

1.3.6.1.4.1.1588.3.1.8.1.1.1.8

Syntax: Unsigned32

Read-only

The value of the receiver optical signal power for the lane in the interface, measured in microwatt.

bcsiOptMonLaneTxBiasCurrent

1.3.6.1.4.1.1588.3.1.8.1.1.1.9

Syntax: SnmpAdminString

Read-only

The Tx Bias Current. It is measured in mA, and is followed by whether this is a normal value, high/low warning, or an alarm.