rmon collection history 
 
   
  Collects Ethernet group statistics for later retrieval. 
  
 Syntax
 
	  
		rmon collection history 
		 
		  number 
		  [ 
		  buckets 
		  bucket_number 
		  | 
		  interval 
		  seconds 
		  | 
		  owner 
		  name 
		  ] 
		 
	 
 
	  
		no romn collection history 
		 
		  number 
		 
	 
  
	 Command Default
 
		 RMON history collection is not enabled. 
		
 
	 
 
	 Parameters
 
		 
		   
			 -  
				 
				  number 
				 
			 
  
			 - Specifies the RMON collection control index value. Valid values range from 1 through 65535. 
			 
  
		   
		   
			 -  
				 
				  buckets 
				  bucket_number 
				 
			 
  
			 - Specifies the maximum number of buckets for the RMON collection history. Valid values range from 1 through 65535. 
			 
  
		   
		   
			 -  
				 
				  interval 
				  seconds 
				 
			 
  
			 - Specifies the alarm sample interval in seconds. Valid values range from 1 through 3600. The default value is 1800. 
			 
  
		   
		   
			 -  
				 
				  owner 
				  name 
				 
			 
  
			 - Specifies the identity of the owner. The maximum number of characters is 15. 
			 
  
		   
		
 
	 
 
	 Modes
 
		 Interface subtype configuration mode 
		
 
	 
 
	 Usage Guidelines
 
		 This command collects periodic statistical samples of Ethernet group statistics on a specific interface for later retrieval. 
		
 
		 Enter 
		  no rmon collection history 
		  number to disable the history of statistics collection. 
		
 
		 
	 
 Examples
 
	  
		 To collect RMON statistics, with an RMON collection control index value of 5 for the owner named admin, on a specific Ethernet interface: 
		
 
		 
		device# configure terminal
device(config)# interface ethernet 1/6 
device(conf-if-eth-1/6)# rmon collection history 5 owner admin