configure flowmon group
configure flowmon group
group_name
Description
Configures a created group where Flow Monitor sends information.
Syntax Description
group
|
Specifies the Flow Monitor group. |
group_name |
Specifies the assigned name of the Flow Monitor
group. Range is 32 characters. |
Usage Guidelines
Optional configuration parameters include the following:
- max-flow-age is the maximum age of any flow related to the
group in milliseconds. The minimum value is 100ms. The default value is 60,000ms
(one minute), and the maximum value is 4294967295ms (a 32-bit unsigned integer).
Flow aging cannot be disabled.
- limit is the maximum number of flows allowed in the flow
database for this group. The minimum value is 32 and the maximum value is the
maximum number of flows for the switch type.
- k-mirror specifies the mirror_name. If
flow-class-id is specified, then
k-mirror cannot be specified. The user can clear the
k-mirror using the none option. Traffic is mirrored to the
same collector assigned to the group.
- flow-class-id_value is a user-assigned number between 5 and
255. If k-mirror is specified, then this value cannot be
specified. The user can clear the value by using the none
option.
Example
The following command configures the Flow Monitor group with the name
'src-ipv4-address':
# configure flowmon group src-ipv4-address
History
This command was first available in ExtremeXOS 32.2.
Platform Availability
This command is available on ExtremeSwitching 5420, 5520, and 5720 series switches.