Removing a Power Supply Module

Follow this procedure to remove a power supply module from the C5215 controller:

Caution

Caution

You can hot-swap the power supply without turning the system down only if the system is configured with two power supply modules. Both power supply modules need to be operating in a 1+1 Redundant configuration.
Note

Note

Currently, the C5215 controller unit ships with just one power supply and you have the option to purchase the additional power supply (order part number 30522 WS-PSI-C5215-750W-01).
Danger
Systems with a single power supply installed or a system operating in a 2+0 non-redundant power mode, MUST be powered OFF before removing the power supply from the system.
  1. Detach the power cord from the power supply unit to be removed.
  2. Using the handle in the bottom of the power supply module, pull the power supply from the system while pushing the green latch in the direction indicated in the image.
    Click to expand in new window
    Removing a Power Supply Module
    _Graphics/c5215_removing_a_power_supply.png