Important Deployment Considerations
Consider the following items before deploying ISW-Series
switches.
Generation deployment
considerations
- Industrial grade SFPs, with
maximum temperatures of up to 85°C, are required for extended temperature
operations.
- ISW-Series switches are
fan-less. In order to achieve the rated operating temperature, the switches
require an airflow of 40 to 100-LFM.
ISW-4W-4WS-4X deployment
considerations
- SFPs are the primary component at
risk for exceeding their thermal limits. SFPs will maintain operation in a safe
environment through the reduction of PoE power in the system.
- When the system enters
operational restriction mode due to thermal limits, the PoE power is reduced
from 360W total to 180W total. The highest numbered ports drop PoE in decreasing
order until the PoE power is at or under 180W.
- In the event the reduction to
180W of PoE power is insufficient, ALL PoE power delivery is turned off.
- If the system continues to
overheat, the SFP TX/RX is turned off until the system cools down below 65°C
(ambient).
ISW-24W-4X deployment
considerations
- System operational specifications
as provided are for when the unit is racked and maintains 2-RU of separation
above and below the unit, using 5-RU of total rack space.
- When the unit is racked and
maintains only 1-RU of separation above and below the unit, using 3-RU of total
rack space, the thermal operational range is reduced.
- When the unit is racked and does
not provide any separation from adjacent racked equipment, using 1-RU of total
rack space, the thermal operational range is extremely limited.
- The system can support 720W of
total PoE power. However, that is limited to distribution at a maximum of 240W
for each set of 8 ports (1-8, 9-16, 17-24).
- SFPs are the primary component at
risk for exceeding their thermal limits. SFPs will maintain operation in a safe
environment through the reduction of PoE power in the system.
- When the system enters
operational restriction mode due to thermal limits, all the right-most 8-ports
(ports 17-24) drop PoE power.
- When the system uses the SDR-960W
PSU, it can achieve 720W of PoE power if the ambient temperature is under 60°C.
Dual PSUs are required to operate at 720W of PoE if the temperature is over
60°C.