Configuring a CFM Segment

Use the following commands to configure a CFM segment.

Some of these commands are optional and, if not configured, the default values are used. The following table lists the default values for delay measurement for a CFM segment.

Table 1. Default Values for Delay Measurement for a CFM Segment
Configuration Default Values

Transmit interval

10 seconds

Window

60 frames

Timeout

50 milliseconds

Alarm threshold

10%

Clear threshold

95%

Dot1p priority

6

The following table lists the default values for loss measurement for a CFM segment.
Table 2. Default Values for Loss Measurement for a CFM Segment
Configuration Default Values

LMM Transmit interval

90 seconds

Dot1p priority

6

Window

1200 frames

SES threshold

0.01

Consecutive available count

4

Note

Note

The statistics for a particular transmission are preserved until the user triggers the transmission once again or if clear counters cfm segment is triggered from the CLI.