Configure Device Classification Thresholds

To understand different visitor types and to increase analytical data accuracy, you must correctly configure device classification thresholds.

Device classification threshold values depend on many factors and varies based on the following:
  • Deployment
  • Location and size of the regions
  • Sensor placements within a region.

ExtremeLocation Essentials classifies visitors into the following categories by calculating the Received Signal Strength Indicator (RSSI) and dwell time thresholds as follows:

Table 1. Visitor Classification
Outside Visitors Inside Bounced Visitors Inside Engaged Visitors
Visitors in the vicinity of the site but not entering the site.

Determined by observed WIFI RSSI values.
Visitors who enter the site but leave in a short time.

Determined by the observed WIFI RSSI values and the site dwell time.

Visitors who enter the site and stay for more than a specified time.

Determined by the observed WIFI RSSI values and the site dwell time.

The Threshold window allows for the following:
  • Configuring fields to classify visitors to the site
  • Setting up thresholds for device categorization based on zones
  • Setting up the different age outs for devices seen at the site.

Use the Signal Strength slider to set values for device classification as one of the following:
  • Ignored Devices
  • Outside Devices
  • Inside Devices.

Table 2. Device Classification
Ignored Devices Inside Devices Outside Devices
ExtremeLocation Essentials ignores devices when the signal strength from the device is below the signal strength value set by the first slider knob. An Inside Device has a signal strength reading that is above the signal strength value set by the second slider knob. An Outside Device has a signal strength reading that is between the two knobs of the signal strength slider.
The red section of the signal strength slider displays the signal strength value. The green section of the signal strength slider displays Inside Devices signal strength values. The orange section of the signal strength slider displays Outside Devices signal strength values.
ExtremeLocation Essentials do not track Ignored Devices for analysis.

Use the Dwell Time slider to set device classification values as one of the following:
  • Outside
  • Inside Bounce
  • Inside Engaged.

Table 3. Dwell Time Device Classification
Outside Devices Inside Bounced Inside Engaged
Outside devices are seen in the site for a duration that is less the duration set by the first slider knob. Inside Bounced devices are seen at the site for a duration between the times indicated by the two knobs of the Dwell Time slider. Inside Engaged devices are seen in the site for a duration greater than the duration set by the second slider knob.
The orange section of the Dwell Time slider displays the device classification threshold. The light green section of the Dwell Time slider displays the device classification threshold. The dark green section of the Dwell Time slider displays the device classification threshold.

Perform the following steps to configure device classification thresholds.

  1. In the main navigation bar on the ExtremeLocation Essentials screen, select, Settings
  2. Select Thresholds.
  3. Use the Signal Strength and Dwell Time sliders to set thresholds.
  4. Select Save.

    Signal Strength & Dwell Time Screen

    Note

    Note

    Threshold changes are not updated in real-time.