Environmental

  • Environmental Specifications
  • EN/ETSI 300 019-2-1 v2.1.2 (2000 - 2009) - Class 1.2 Storage
  • EN/ETSI 300 019-2-2 v2.1.2 (1999 - 09) - Class 2.3 Transportation
  • EN/ETSI 300 019-2-3 v2.1.2 (2003 - 04) - Class 3.1e Operational
  • EN/ETSI 300 753 (1997-10) - Acoustic Noise
  • ASTM D3580 Random Vibration Unpackaged 1.5G
  • Environmental Operating Conditions
  • Front-to-back airflow: 0°C to 50°C (32°F to 122°F) up to 1800m (6000 ft)
  • Front-to-back airflow: 0°C to 45°C (32°F to 113°F) above 1800m (6000 ft)
  • Back-to-front airflow: 0°C to 45°C (32°F to 113°F) up to 1800m (6000 ft)
  • Back-to-front airflow: 0°C to 40°C (32°F to 104°F) above 1800m (6000 ft)
  • Humidity: 5% to 95% relative humidity, non-condensing
  • Altitude: 0 to 3,000 meters (9,850 feet)
  • Operational shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks
  • Operational random vibration: 3 to 500 Hz at 1.5 G rms
  • Packaging and Storage Specifications
  • Temp: -40°C to 70°C (-40°F to 158°F)
  • Humidity: 5% to 95% relative humidity, non-condensing
  • Packaged Shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks
  • Packaged Vibration: 5Hz to 62Hz at velocity 5 mm/s, 62Hz to 500Hz at 0.2 G
  • Packaged Random Vibration: 5Hz to 20Hz at 1.0 ASD w/–3 dB/oct. from 20Hz to 200Hz
  • Packaged Drop Height: 14 drops minimum on sides and corners at 42 inches (<15 kg box)