
X670G2-48x-4q.1 # enable vpex X670G2-48x-4q.1 # reboot Are you sure you want to reboot the switch? (y/N) Yes Slot-1 VPEX X670G2-48x-4q.1 #

Note
After reboot, command prompt changes to show that you are in VPEX mode.Slot-1 VPEX X670G2-48x-4q.1 # enable sharing 1:10 group 1:10-1:11 Slot-1 VPEX X670G2-48x-4q.2 # enable sharing 1:20 group 1:20-1:21
Slot-1 VPEX X670G2-48x-4q.1 # configure vpex port 1:10 slot 33
WARNING: This command will remove VLAN membership from the
port 1:10.
Do you want to continue? (y/N)Yes
Slot-1 VPEX X670G2-48x-4q.2 # configure vpex port 1:20 slot 34
WARNING: This command will remove VLAN membership from the
port 1:20.
Do you want to continue? (y/N)Yes
Slot-1 VPEX X670G2-48x-4q.3 # show slot
Slots Type Configured State Ports Flags
--------------------------------------------------------------------------------
Slot-1 X670G2-48x-4q X670G2-48x-4q Operational 64 M
Slot-33 V400-48p-10GE4 Operational 52
Slot-34 V400-48p-10GE4 Operational 52
Flags : M - Backplane link to Master is Active
B - Backplane link to Backup is also Active
D - Slot Disabled
I - Insufficient Power (refer to "show power budget")
Slot-1 VPEX X670G2-48x-4q.9 # show vpex
Virtual Port Extender: Enabled
Cascade
Port Slot
=============
1:10 33
1:20 34

Note
Observe that the show slot command shows the CB as slot 1 with the two BPEs as slots 33 and 34.
Note
Observe that the show vpex command shows that ports 1:10 and 1:20 are the cascade ports connecting to the BPEs.Slot-1 VPEX X670G2-48x-4q.1 # configure vlan Default delete port all Slot-1 VPEX X670G2-48x-4q.2 # create vlan v100 tag 100 Slot-1 VPEX X670G2-48x-4q.3 # configure vlan v100 add port 33:1-2, 34:1-2, 1:7 tagged
Slot-1 VPEX X670G2-48x-4q.3 # show port 33:1-2, 34:1-2, 1:7 statistics no-refresh
Port Link Tx Pkt Tx Byte Rx Pkt Rx Byte Rx Pkt Rx Pkt Tx Pkt Tx Pkt
State Count Count Count Count Bcast Mcast Bcast Mcast
========= ===== =========== =========== =========== =========== ===========
33:1 R 0 0 0 0 0 0 0 0
33:2 R 0 0 0 0 0 0 0 0
34:1 R 0 0 0 0 0 0 0 0
34:2 R 0 0 0 0 0 0 0 0
1:7 R 0 0 0 0 0 0 0 0
========= ===== =========== =========== =========== =========== ===========
Slot-1 VPEX X670G2-48x-4q.13 # show port 33:1-2, 34:1-2, 1:7 qosmonitor no-refresh
Port Qos Monitor
Port QP1 QP2 QP3 QP4 QP5 QP6 QP7 QP8
Pkt Pkt Pkt Pkt Pkt Pkt Pkt Pkt
Xmts Xmts Xmts Xmts Xmts Xmts Xmts Xmts
================================================================================
33:1 0 0 0 0 0 0 0 0
33:2 0 0 0 0 0 0 0 0
34:1 0 0 0 0 0 0 0 0
34:2 0 0 0 0 0 0 0 0
1:7 0 0 0 0 0 0 0 0
Print
this page
Email this topic
Feedback