Tip
For an easier, automatic way to add or replace a node, see Automatically Adding or Replacing Nodes in a Stack.Adding a new switch, or node, to an active stack topology is similar to bringing up a new stack.
Note
If the node being added is actually a replacement node for one that was previously removed, see Replacing a Node with the Same Switch Type or Replacing a Node with a Different Switch Type.Note
If the stack will use MPLS, only the following switch types can act as primary and backup: Extreme Switching X460-G2, X670-G2; X465, X590, X690, X695, or X870.Review the general and model-specific configuration guidelines for the node you are installing. These guidelines are described in ExtremeSwitching and Summit Switches: Hardware Installation Guide for Switches Using ExtremeXOS Version 31.4 .
The examples in the following procedure assume that your current stack has four nodes and you are adding a new node at slot 5.
To manually add a node to a stack:
Switch.3 # configure stacking node-address 00:04:96:26:6c:92 slot-number 5 This command will take effect at the next reboot of the specified node(s).
For more information about cabling, see ExtremeSwitching and Summit Switches: Hardware Installation Guide for Switches Using ExtremeXOS Version 31.4 .
Slot-1 Stack.1 # show stacking Stack Topology is a Ring Active Topology is a Ring Node MAC Address Slot Stack State Role Flags ------------------ ---- ----------- ------- --- *00:04:96:9c:e4:39 1 Active Master CA- 00:04:96:9b:c1:34 2 Active Backup CA- 00:04:96:9e:5c:76 3 Active Standby CA- 00:04:96:9c:53:b6 4 Active Standby CA- 00:04:96:26:6c:92 5 Active Standby CA- * - Indicates this node Flags: (C) Candidate for this active topology, (A) Active Node (O) node may be in Other active topology Slot-1 Stack.2 # show slot Slots Type Configured State Ports -------------------------------------------------------------------- Slot-1 X440G2-24t-10G4 Operational 28 Slot-2 X440G2-24x-10G4 Operational 28 Slot-3 X440G2-12p-10G4 Operational 16 Slot-4 X440G2-12t-10G4 Operational 16 Slot-5 X440G2-12t-10G4 Operational 16 Slot-6 Empty 0 Slot-7 Empty 0 Slot-8 Empty 0