Resolved Issues in ExtremeXOS 16.1.2-Patch1-1
The following issues were resolved in ExtremeXOS 16.1.2-Patch1-1. ExtremeXOS 16.1.2-Patch1-1 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, and ExtremeXOS 16.1.2. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0059165 | OSPFv3 crash occurs after deleting newly added VLANs. |
xos0059560 | After reboot, OSPFv3 fails to select the best path to destination. |
xos0059569 | OSPFv3 external routes flap and traffic loss occurs when introducing new ABR which has reachability to destination. |
xos0061505 | After a topology change in the network, BGP routes requiring two levels of recursive lookup are programmed in hardware with incorrect next hops. |
xos0062017 | DHCP trusted port configuration is lost after disabling, and then re-enabling LAG. |
xos0062045 | LLDP packets are tunnelled over L2VPn. |
xos0062290 | Due to ExtremeXOS reflection RSTP BPDU support, upstream bridges believe that they are receiving their own BPDUs (contain the bridge's ID), thus causing multisource events during topology changes, which can cause slow convergence times when lp is configured (upwards of 30 seconds). |
xos0062428 | Member ports with a modified speed configuration that is different than the master port should not be allowed in LAG. |
xos0062441 | The process rtMgr ends unexpectedly when IPv6 static route is deleted. |
xos0062460 | The show configuration command output shows incorrect ELRP configuration |
xos0062674 | UPM profile fails to set the variables received from the RADIUS server using VSA 212. |
xos0062709 | Due to the stronger hash algorithm, if you create accounts in ExtremeXOS 16.1, and then downgrade to versions earlier than ExtremeXOS 16.1, you may encounter problems using the passwords for these accounts. For more information about this issue, visit: http://extr.co/1KfSszY. |
xos0062719 | Allow use of 3rd-party optics without any additional license. |
xos0062728 | OSPFv3 best path is not selected after issuing restart ports all in peer switch. |
xos0062756 | Output of show network-clock gptp current-set command shows incorrect timestamp for "Last GM Change Event". |
xos0062789 | Disabling learning on LAG ports does not flush FDB entries. |
xos0062914 | The process mcmgr ends unexpectedly after receiving corrupted IGMPv3 join packets on MLAG ports. |
xos0062965 | Policy process ends unexpectedly with signal 6 when master node goes down. |
xos0063071 | Add support for ONEPolicy IP socket classification. |
xos0054348 | Cannot delete flow names after deleting, and then creating, the flow while the ACL is installed. |
xos0057538 | OSPFv3 fails to select the best cost external route. |
xos0057574 | After multiple disable/enable OSPFv3, OSPFv3 routes are not advertised to route manager. |
xos0057575 | OSPFv3 external routes are not updated in the routing table after link flap events. |
xos0057583 | In OSPFv3, after adding an ASBR, new route is received, but it is not added to routing table even though it is a best route. |
xos0057584 | When there are equal cost ASBR routes, OSPFv3 is sharing only one path to route manager. |
xos0059341 | OSPFv3 external routes are flushed after interface cost is changed if multiple ABRs are present for an area. |
xos0059446 | OSPFv3 external routes are flushed when ports from OSPFv3 user VR are deleted. |
xos0060463 | OSPFv3 external routes are flushed after the commandrestart ports all is executed in area border router. |
xos0061890 | Zero-Touch Provisioning should not run when default.xsf file is present. |
xos0061965 | Configuring ESRP member VLANs (VRRP-enabled) produces errors. |
xos0062380 | Switch rejects incorrect LSP configurations as expected, but this operation still uses LSP indexes in hardware. |
xos0062504 | You can set a GPTP "peer delay current interval" outside of the correct range of -3 to 17. |
xos0062508 | When a port is added in a loopback VLAN, OSPFv3 route is not advertised with /128 mask. |
xos0062824 | Extra ACL slice allocated for QoS even with default configuration. |
Summit X430 Series Switches | |
xos0059486 | On Summit X430 series switches, optics are not detected after repeated removal and reinsertion of optics when CPU is busy. |
SummitStack | |
xos0062800 | Stack node fails because of license mismatch for 3rd-party optics. |
Summit X460-G2 Series Switches | |
xos0062855 | On the Summit X460-G2 series switches, VPLS packets are forwarded with two tags when the service VLAN ports are also members of an untagged VMAN. |
Summit X670 Series Switches | |
xos0063052 | Traffic loss occurs on computer connected to Summit X670v-48t switches when the connected switch port is oversubscribed in 100 MB mode. |
BlackDiamond 8800 Series Switches | |
xos0061663 | In c- and e-series I/O modules after MLAG port up/down events, it takes long time to learn FDB entries. |
BlackDiamond X8 Switches | |
xos0063057 | On BlackDiamond X8 series switches, an IPv6 multicast group, such as FF02::1, is incorrectly treated as a local address. |