Resolved Issues in ExtremeXOS 16.1.2-Patch1-1

The following issues were resolved in ExtremeXOS 16.1.2-Patch1-1. ExtremeXOS 16.1.2-Patch1-1 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, and ExtremeXOS 16.1.2. For information about those fixes, see the release notes for the specific release.

expand icon

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) for ExtremeXOS 16.1.2-Patch1-1

CR Number Description
General
xos0059165 OSPFv3 crash occurs after deleting newly added VLANs.
xos0059560 After reboot, OSPFv3 fails to select the best path to destination.
xos0059569 OSPFv3 external routes flap and traffic loss occurs when introducing new ABR which has reachability to destination.
xos0061505 After a topology change in the network, BGP routes requiring two levels of recursive lookup are programmed in hardware with incorrect next hops.
xos0062017 DHCP trusted port configuration is lost after disabling, and then re-enabling LAG.
xos0062045 LLDP packets are tunnelled over L2VPn.
xos0062290 Due to ExtremeXOS reflection RSTP BPDU support, upstream bridges believe that they are receiving their own BPDUs (contain the bridge's ID), thus causing multisource events during topology changes, which can cause slow convergence times when lp is configured (upwards of 30 seconds).
xos0062428 Member ports with a modified speed configuration that is different than the master port should not be allowed in LAG.
xos0062441 The process rtMgr ends unexpectedly when IPv6 static route is deleted.
xos0062460 The show configuration command output shows incorrect ELRP configuration
xos0062674 UPM profile fails to set the variables received from the RADIUS server using VSA 212.
xos0062709 Due to the stronger hash algorithm, if you create accounts in ExtremeXOS 16.1, and then downgrade to versions earlier than ExtremeXOS 16.1, you may encounter problems using the passwords for these accounts. For more information about this issue, visit: http://extr.co/1KfSszY.
xos0062719 Allow use of 3rd-party optics without any additional license.
xos0062728 OSPFv3 best path is not selected after issuing restart ports all in peer switch.
xos0062756 Output of show network-clock gptp current-set command shows incorrect timestamp for "Last GM Change Event".
xos0062789 Disabling learning on LAG ports does not flush FDB entries.
xos0062914 The process mcmgr ends unexpectedly after receiving corrupted IGMPv3 join packets on MLAG ports.
xos0062965 Policy process ends unexpectedly with signal 6 when master node goes down.
xos0063071 Add support for ONEPolicy IP socket classification.
xos0054348 Cannot delete flow names after deleting, and then creating, the flow while the ACL is installed.
xos0057538 OSPFv3 fails to select the best cost external route.
xos0057574 After multiple disable/enable OSPFv3, OSPFv3 routes are not advertised to route manager.
xos0057575 OSPFv3 external routes are not updated in the routing table after link flap events.
xos0057583 In OSPFv3, after adding an ASBR, new route is received, but it is not added to routing table even though it is a best route.
xos0057584 When there are equal cost ASBR routes, OSPFv3 is sharing only one path to route manager.
xos0059341 OSPFv3 external routes are flushed after interface cost is changed if multiple ABRs are present for an area.
xos0059446 OSPFv3 external routes are flushed when ports from OSPFv3 user VR are deleted.
xos0060463 OSPFv3 external routes are flushed after the commandrestart ports all is executed in area border router.
xos0061890 Zero-Touch Provisioning should not run when default.xsf file is present.
xos0061965 Configuring ESRP member VLANs (VRRP-enabled) produces errors.
xos0062380 Switch rejects incorrect LSP configurations as expected, but this operation still uses LSP indexes in hardware.
xos0062504 You can set a GPTP "peer delay current interval" outside of the correct range of -3 to 17.
xos0062508 When a port is added in a loopback VLAN, OSPFv3 route is not advertised with /128 mask.
xos0062824 Extra ACL slice allocated for QoS even with default configuration.
Summit X430 Series Switches
xos0059486 On Summit X430 series switches, optics are not detected after repeated removal and reinsertion of optics when CPU is busy.
SummitStack
xos0062800 Stack node fails because of license mismatch for 3rd-party optics.
Summit X460-G2 Series Switches
xos0062855 On the Summit X460-G2 series switches, VPLS packets are forwarded with two tags when the service VLAN ports are also members of an untagged VMAN.
Summit X670 Series Switches
xos0063052 Traffic loss occurs on computer connected to Summit X670v-48t switches when the connected switch port is oversubscribed in 100 MB mode.
BlackDiamond 8800 Series Switches
xos0061663 In c- and e-series I/O modules after MLAG port up/down events, it takes long time to learn FDB entries.
BlackDiamond X8 Switches
xos0063057 On BlackDiamond X8 series switches, an IPv6 multicast group, such as FF02::1, is incorrectly treated as a local address.