Resolved Issues in ExtremeXOS 16.1.2-Patch1-4

The following issues were resolved in ExtremeXOS 16.1.2-Patch1-4. ExtremeXOS 16.1.2-Patch1-4 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, and ExtremeXOS 16.1.2. For information about those fixes, see the release notes for the specific release.

expand icon

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) for ExtremeXOS 16.1.2-Patch1-4

CR Number Description
General
xos0063359 The process rtmgr might end unexpectedly after executing disable bgp, and then enable bgp, or after disable port, and then enable port, or after rebooting a switch containing BGP routes.
xos0063506 Traceroute MAC address in CFM domain does not return information about destination switch.
xos0063380 Error message appears after rebooting switch with OSPF configuration: "Error while loading "ospfInterface": ERROR: 0.0.0.0 is not a valid configured neighbor for interface".
xos0057269 SNMP trap extremeIpSecurityViolation is sent with incorrect VLAN description.
xos0061507 SNMPget on EXTREME-SOFTWARE-MONITOR table returns value with incorrect OID.
xos0061781 Identity manager entries become stale when clients are moved from one port to another in sub-VLANs.
xos0061788 The process devmgr ends unexpectedly during snmpwalk when continuous EMS logs are sent to the switch console.
xos0061797 Dot1x client moves to authentication failure VLAN if authentication failed due to incorrect supplicant password or framework failure, such as error in VLAN movement, etc.; even if web-based NetLogin is enabled.
xos0061855 Configured OSPF neighbor is not retained after rebooting.
xos0062240 Port that was administratively disabled becomes up after enabling rx pause.
xos0062366 After reboot, DHCP binding entries are not restored via vr-default.
xos0062537 HAL crash occurs when redirect-port-list action contains more than 64 ports.
xos0062618 ELRP forgets the disabled port information if the port is deleted from another VLAN that also has ELRP enabled. As a result, the disabled port stays disabled unless manually enabled.
xos0062619 SSH access-profile using policy does not work with IPv6 addresses.
xos0062629 Clearflow rule does not work properly if there is dot(.) in the ACL counter.
xos0062879 Transceiver information shows same Rx power value for 4x10G partition ports even though some ports are in ready state.
xos0063089 Kernel oops triggered infrequently during continuous addition/deletion of ARP entries for long durations.
xos0063108 NAS Identifier attribute should be sent in RADIUS accounting requests.
xos0063120 Error message "CFP2 modules >= 18 W unsupported" incorrectly appears for Finisar Corp CFP2 LR4 optics.
xos0063172 ACL action "redirect-port-list" does not take effect when another slice has a rule to match all packets with deny action.
xos0063248 NTP MD5 authentication with NTP server is failing.
xos0063257 Saving configuration fails/times-out when VLANs added to a mirror filters are renamed.
xos0063271 Layer 3 packets in non-default virtual routers are slow-path forwarded after disabling MPLS in the peer switch.
xos0062494 Source MAC addresses learned through MVRP packets on a blocked port (STP) cause traffic to be dropped.
xos0062701 HAL timeout occurs while rebooting a stack with STP configuration.
xos0062754 VPLS traffic egresses out with dot1q tag when secondary EtherType is configured.
xos0063090 Netlogin client does not move into authfail VLAN when user is absent from local database.
xos0063207 Error occurs while adding LAG ports as tagged in one VMAN and untagged in another VMAN, even though the VMAN EtherType is primary.
xos0062821 ACL rules installed are not mapped to single virtual group even though ACL action-resolution mode is highest-priority.
BlackDiamond 8800 Series Switches
xos0062009 In BlackDiamond 8800 series switches with XL modules, clearing FDBs when there is a loop causes the FDBs to lose synchronization across slots or switching units.
SummitStack
xos0063242 Stacks configured as DHCP clients do not respond to pinging after failover.
xos0062949

HAL process ends unexpectedly in stack after executing the following commandsL

debug hal configure stacking pdu-trace mask 0xf

debug hal configure stacking pdu-trace capture cap_file

xos0063344 With MLAG and LAG configurations, when a stack node comes up after a reboot, FDB entries flooded from other slots are programmed on wrong ports internally.
xos0063349 Switch stops responding to SNMP requests if SNMP get for multiple OIDs is continuously initiated.
xos0062367 ACL process ends unexpectedly on repeated refresh of ACL policy with clear-flow action.
Summit X440 Series Switches
xos0062621 On Summit X440-8p switches, the show fan command output displays that the fan is unsupported.
Summit X460 Series Switches
xos0063206 Cannot add L2 entries in hardware due to a full L2 table caused by hash collisions.
Summit X670 Series Switches
xos0059514 On Summit X670V-48x switches, after multiple reboots, 40G ports can remain in ready state, rather than coming to active state, which impacts the traffic passing through those ports.
xos0061559 Enabling OpenFlow on VLANs causes double-wide ACL slice to be used even though it can fit in single-wide slice.
xos0062487 QSFP+ optics are detected as unsupported after rebooting.
xos0063137 Known unicast traffic is not shared between the stacking high-gig trunk ports.
Summit X670-G2 Series Switches
xos0061791 On SummitStacks containing master and standby nodes of different switch platforms, the standby node may go to failed state after a node reboot.
xos0063204 Traffic stops on LAG ports when frequently modifying the sharing group.