The following issues were resolved in ExtremeXOS 16.1.2. ExtremeXOS 16.1.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, and ExtremeXOS 16.1. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0057374 | Switch odometer value is reinitialized when Master Switch Fabric Module (MSM) fails to read the value. |
xos0058669 | DHCPv6 client: After changing the client identifier type, and then restarting the port, old IPv6 addresses are not released, causing the show vlan command to show multiple IPv6 addresses. |
xos0059942 | SSH connection ends when show commands produce lengthy output. |
xos0059989 | Configuring non-persistent command using UPM script shows dirty bit(*) in the prompt. |
xos0060909 | In UPM profiles the variable EVENT.TIME incorrectly has the current time rather than the time when the event was queued/triggered. |
xos0061085 | Kernel oops occurs while deleting VR with enable BGP export and IPARP proxy configurations. |
xos0061173 | L2PT packets are dropped when ingress port is configured with software learning. |
xos0061219 | Parallel-mode-enabled DHCP offer is sent using primary IPv4 address to the client for multiple offers received from server for different IPv4 addresses. |
xos0061331 | Bootprelay for VRF is not supported. Commands to configure bootprelay should reflect this. |
xos0061379 | Switch temperature value retrieved using SNMP get operation is incorrect. |
xos0061445 | After creating and enabling an STPD, the command configure "Default" add ports 1 tagged stpd "s1" adds ports to the Default VLAN, but not with STPD domain, even though the error Command Aborted and no changes were made appears. |
xos0061565 | The TCL function, “clock scan," generates errors with default time zone configuration. |
xos0061656 | Nodes remain in the "FDBSync" state due to temp-flooding while rebooting the stack. |
xos0062018 | For IPv6 routes with mask lengths greater than 64-bits, IPv6 unicast packets destined for the switch CPU can be dropped if another IPv6 route is present with a matching prefix and mask length less than or equal to 64-bits. This issue affects Summit X440, X460-G2, X670-G2, X770 switches, BlackDiamond 8800 G48Te2 I/O modules, and BlackDiamond X8 100G I/O modules. |
xos0062128 | L3VPN traffic is not forwarded after executing disable port and enable port in MPLS core network. |
xos0062133 | STP flush event does not happen after ports are quickly disabled, and then enabled. |
xos0062271 | CLI memory leak occurs when executing show commands with include option through script. |
xos0062427 | EDP process ends unexpectedly when CDP packets without portId TLV are received. |
xos0062472 | Source MAC addresses learned through CDP packets received on EAPS-blocked ports cause traffic to be dropped. |
xos0062710 | On BlackDiamond 8800 or BlackDiamond X8 series switches, with Distributed IP ARP mode on, ECMP routes are sometimes not installed when gateways flap. |
BlackDiamond X8 Series Switches | |
xos0058950 | XFP optics appear as unsupported in the output of the show port configuration command. |
xos0060085 | The command show iproute reserved-entries statistics displays the incorrect maximum value for IPv4 local hosts: "16,384" versus the correct value of "65,533" for BDX8 XL modules. |
xos0060264 | The output of the show port transceiver info command for optics inserted in 40G/100G ports might be abnormally lengthy if the same command is executed from two different CLI sessions simultaneously. |
xos0061186 | Bytes counter associated with show port utilization command output displays inaccurate value for 100G ports when utilization exceeds 40%. |
xos0061639 | Packets ingressing on VLAN-bridged interfaces (Layer 2 VLANs) are not forwarded when the destination MAC address is the same as the switch MAC address, and the switch has at least one Layer 3 interface. |
xos0061902 | BlackDiamond X8 series switches use VLAN instance as index instead of router interface (rtif) for ARP entries. |
xos0062306 | Packets get reflected with same tag on port-specific, tag-enabled VLANs after failover. Issue happens only on switches having both port-specific tags and MPLS RSVP-TE configurations. |
xos0062477 | BlackDiamond X8 series switches' management ports flap and show Detected Tx unit hung error messages. |
xos0062499 | Multicast packets are dropped in Layer 2 bridged VLANs. |
BlackDiamond 8800 Series Switches | |
xos0060891 | While sending continuous join and leave, as well as multicast streams multiple times allowing the streams to age out, kernel error messages appear for add/delete operation with reason Entry not found. |
xos0061822 | HAL process ends unexpectedly during failover when switches have ACL policies without meter action. |
xos0061994 | Packets are not forwarded over VPWS after rebooting BlackDiamond 8800 switches. |
xos0062060 | FDB entries are not programmed in hardware even though hardware resources have sufficient capacity. |
xos0062535 | Matched packets are dropped for a subset of rules while using redirect-port-list action. |
Summit Family | |
xos0059007 | For Summit X670-G2-48x and X770 switches, QSFP+ to SFP+ adapter support is added to work with all optical SFP+ transceivers with the exception of LRM and passive copper direct attach cables. |
xos0062782 | Some existing Summit X430 or X440 configurations requiring Access Lists may stop working after upgrading to ExtremeXOS 15.7.2 or 15.6.3. |
xos0062113 | The show power command output does not display power usage for PSUs with part numbers starting with “800515”. |
xos0061886 | SNMP master process ends unexpectedly with signal 6 with certain sequence of snmpbulkget and snmpget. |
SummitStack | |
xos0062570 | In SummitSacks, executing the command enable sflow ports all enables sFlow inappropriately on stacking ports. |
xos0057835 | In SummitStacks, clear-flow sampling period is incorrectly calculated. |
xos0061108 | With authentication mode set to optional, MAC addresses exceeding the allowed number of users are not learned in the However, FDB. Traffic is forwarded correctly by the default policy. |
xos0061614 | On Summit X450-G2/X440 mixed stacks, executing the command show stacking causes the master to become unresponsive after rebooting backup. |
xos0061784 | Failover with ONEPolicy enabled with thousands of user sessions authenticated may result in some sessions being tracked incorrectly on the new master, which may result in inconsistent session behavior for those sessions. |
xos0061799 | Precedence order between policy port rules and policy MAC-based rules is not preserved following a master/backup Failover. |
xos0061847 | If ONEPolicy is enabled and Summit X670-G2 or X770
series switches are inserted and/or a slot is rebooted, the Summit X670-G2 or X770
fails to properly enable ONEPolicy. An error message similar to the following
appears:mm/dd/yyyy hh:mm:ss.ms <Erro:HAL.IPv4ACL.Error> Slot-2: pibAclWrapReserveSlices failed for slot 1 unit 1 with rv=-14 |
xos0061957 | HAL process ends unexpectedly during failover when switches have ACL policy without meter action. |
xos0062217 | In SummitStacks with eight nodes and sFlow configuration, Hardware L3 Table full error messages appear when the stacks have a large number of Layer 3 entries. |
xos0062238 | On a stacked system, configuration of a user-defined CoS value's etsysCos8021dPriority using the MIB can return success when the set actually failed (as seen by a subsequent get). |
xos0062522 | In Summit stacking switches, standby slots go to failed state when very large log messages are continuously generated in the switch. |
Summit X430 Series Switches | |
xos0061864 | FDB process consumes more than 20% utilization when Summit X430 switches are configured with 100+ VLANs. |
Summit X440 Series Switches | |
xos0061578 | Configuring NTP on VR-Mgmt is not allowed in virtual router unsupported platforms. |
Summit X450-G2 Series Switches | |
xos0061070 |
Summit X450-G2 1G switches (X450-G2-xxx-GE4) display incorrect log messages when SFP+ optics are inserted into any of the 1G SFP ports. Incorrect Log message example: The configuration for the SF+_LR optic module is not correct - please configure port 50 for auto-negotiation Off and speed 10000 |
xos0061933 | Summit X450-G2 series switches may overheat. |
Summit X460 Series Switches | |
xos0061180 | In Summit X460 stack with mixed alternate and native stacking enabled slots, traffic ingressing one specific slot is not forwarded to other slots. |
xos0061599 | On Summit X460 series switches, after configuring limit learning, traffic is doubled for the non-blackholed MAC addresses, whereas traffic is blocked correctly for blackholed MAC addresses. |
Summit X460-G2 Series Switches | |
xos0061486 | Combo ports have unsupported autonegotiation and half-duplex settings. |
xos0061814 | When NetSight Policy Manager attempts to enable policy, Policy Manager might report success even if there is a failure. The failure is reported properly by EMS message. |
xos0061892 | When policy profile has CoS status enabled without pvid-status enabled, disabling policy does not clean up underlying rules; subsequently, enabling policy may fail. |
xos0062425 | On Summit X460-G2 series switches, the primary port is incorrectly set as 40 when it should be 41. Under certain conditions, this can cause a kernel crash. |
Summit X670 Series Switches | |
xos0061167 | Links become active without a connection with tri-speed Base-T SFP installed. |
Summit X670-G2 Series Switches | |
xos0061818 | After rebooting Summit X670-G2 stacks, links come up after long delay of ~20 minutes when QoS profile is configured on 500+ VLANs. |
ACLs | |
xos0059924 | The output of the command show access-list meter ports displays additional meter name when only one meter is applied using ACL policy. |
xos0060716 | Need support for new ACL action "redirect-vlan" to redirect matched packets to all ports in specified VLANs. |
xos0061922 | Dynamic ACLs applied as "any" fail to install in hardware after upgrading ExtremeXOS from any release other than EXOS 15.3. |
xos0062145 | With QoS configuration, ACL process signal 11 ends unexpectedly after rebooting. |
BGP | |
xos0061411 | Route table installs sub-optimal BGP routes (next-hop) to kernel, while the BGP RIB shows different paths when same routes are received from two different peers in local-RIB. |
xos0062260 | BGP process ends unexpectedly when local address or password is changed for BGP neighbor, and then you immediately execute a BGP show/configuration command. |
Chalet | |
xos0060354 | ExtremeXOS Chalet using IPv6 does not work with HTTPS. |
xos0062016 | Command line process memory leak occurs when accessing switches with Chalet. |
EAPS | |
xos0061038 | Loops occur in EAPS-protected VLANs, after peer reboot, if a VLAN‘s port is also protected by ELSM. |
xos0061385 | EAPS process ends unexpectedly after deleting EAPS shared-port configuration. |
FDP | |
xos0059655 | Error Unable to delete permanent entry appears while deleting static blackhole FDB entries. |
Identity Management | |
xos0061699 | Traffic is dropped when moving idmgr client from one port to another with role-based authentication. |
IP General | |
xos0057672 | The process rtmgr ends unexpectedly when disabling GRE tunnels. |
xos0060796 | Loop created for IGMP query and report packet when port isolation is "ON". |
xos0061129 | In a multi-peer setup with many routes (over 150K), a few routes from the preferred peer do not become active in the BGP RIB. Disabling, and then re-enabling peer, restores all routes. |
xos0061198 | Disabling VPN-VRF affects traffic on another VPN-VRF. |
xos0062705 | Kernel oops can occur after clearing IPMC FDB in a stack. |
MPLS | |
xos0061092 | Traffic forwarding on VPLS-serviced VMAN stops after link flap. |
xos0061662 | When a large number of RSVP-TE LSPs (>250) are signaled to go down because of a link failure, some LSPs do not go down right away. They time out after a few minutes. |
NetLogin | |
xos0058808 | Rarely, MAC addresses of authenticated clients learned on NetLogin-enabled ports are not programmed in hardware. |
xos0060242 | Ports are not removed when unauthenticated UPM profiles are triggered. |
xos0060449 | NetLogin MAC-based mode does not work as expected with PVLANs. |
xos0061450 | Logging on to the switch using HTTPS is permitted if NetLogin is enabled, even though HTTPS is disabled. |
xos0061820 | Dot1x clients move to authentication failure VLAN when web-based NetLogin is enabled globally. |
xos0061837 | When a user is authenticated by NetLogin, but exceeds the allowed per-agent user limits in policy, policy does not signal NetLogin to unauthenticate the user. |
xos0061868 | With protocol order as MAC dot1x, web-based UPM profile is not executed for the client, which is authenticated as MAC. |
QoS | |
xos0060092 | Fetching values using SNMP for "extremePortQosStatsTable" does not work correctly. |
SNMP | |
xos0059964 | SNMP poll for MIB dot3StatsDuplexStatus always returns unknown(1) when ports are configured with auto-negotiation on. |
xos0061945 | SnmpSubagent crash occurs when snmpset executed on the last row in EAPSMbrVlanEntry. |
VLANs | |
xos0054039 | IP multicast traffic is not forwarded on PSTAG VLANs when it shares ports with other IGMP snooping-enabled VLANs or other L3 VLANs. |
xos0061840 | A large VLAN configuration (near capacity for the switch) can stop working after restarting a VLAN client application (for example, restart process eaps) or rebooting due to excessive memory usage. |
xos0062277 | The command show vlan vlan_list does not show information for dynamic VLANs nor the Default VLAN. Error appears. |