Resolved Issues in ExtremeXOS 16.1.3-Patch1-7
The following issues were resolved in ExtremeXOS 16.1.3-Patch1-7. ExtremeXOS 16.1.3-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.
Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) for ExtremeXOS 16.1.3-Patch1-7
CR Number | Description |
---|---|
General | |
xos0056729 | After being deleted from the switch, old configuration files are incorrectly visible in the help menu. |
xos0057931 | After rebooting the switch multiple times, following error log message
appears:<Erro:cm.loadErr> Failed to load configuration: timed out (after 150 seconds) while waiting for all applications to get ready to load configuration on OPERATIONAL ( eaps is still not ready yet). |
xos0061597 | After authenticating a NetLogin client, executing the command clear netlogin state port, and then checking that ID-mgmt has deleted the clients, log displays UnDscvrId EMS message, which does not indicate the identity user. |
xos0062265 | Some legacy commands are not recognized. |
xos0062720 | Unable to save configuration when ACL/CFM is configured on multiple VLANs. |
xos0063332 | Configuration changes to VPLS are not fully retrieved by SNMP walk, which returns values for only few VPLS index. |
xos0063980 | EDP process crash with signal 11 when receiving CDP packet with IPv6 address type. |
xos0064009 | MLAG+EAPS:Traffic forwarding stops after EAPS that include ISC link converges. |
xos0064054 | SNMPwalk on extremeAclStatsTable returns value with port instance instead of ifIndex. |
xos0064055 | Resiliency Enhancement for IPv4 and IPv6 Static Routes feature has been added. |
xos0064151 | Errors occur when removing DHCP configuration from VLANs when LAG ports are added to the VLANs. |
xos0064223 | Need to add an ACL match condition for matching next-hop addresses during the look-up cycle of a packet, so that actions can be taken based on the next-hop a packet is destined for. |
xos0064278 | In a SummitStack or BlackDiamond chassis, FDB is not programmed in hardware after three failovers and fallback. |
xos0064043 | Unable to use a configuration file that has been copied from an existing configuration file. |
xos0064129 | Policy refresh never completes with network-zone configuration. |
xos0064215 | The following log message appears when a subnet is reachable both using MPLS
and non-MPLS:
<Warn:Kern.IPv4FIB.Warning> Slot-4: dest 0x0A420000 / 24 nexthop 0xAC11121E: Unable to add route to unit 1, rc Entry not found. Shadow problem |
xos0064307 | RADIUS accounting configuration is incorrect as shown by the command show conf aaa and is lost after upgrade. |
Summit X430 Series Switches | |
xos0064084 | In Summit X430 series switches, the command show power details displays fan status as "empty". |
Summit X440 Series Switches | |
xos0063627 | ARP is not re-added to hardware after it is removed initially due to the table being full. |
xos0064049 | Need command provision to tune pre-emphasis settings for stacking port on Summit X440 series switches. |
xos0064050 | While running diagnostics on a Summit X440 10G model switch with revision 10 and diagnostics test version 6.0 or above, “Test loopback phy fiber" and "Test snake interface" fail. |
Summit X460-G2 Series Switches | |
xos0063811 | Summit X460-G2 series switches with ExtremeXOS 15.6 through 21.1, have the
following limitations for SyncE input reference frequency:
|
SummitStack | |
xos0061834 | In SummitStacks, the command synchronize stacking slot slot no does not work from master node if the target slot is in failed state. |
xos0061861 | A per-port meter configured on a SummitStack may not be properly configured on the backup node following a reboot. |
BlackDiamond X8 Switches | |
xos0062262 | UDP profile configurations on VLANs do not take effect in BlackDiamond X8 series switches. |
xos0063080 | ACL rule with destination zone match condition does not take effect, since IP address gets installed in reverse order in hardware. |
xos0063958 | BDX8-40G12X-XL module goes into reboot cycle if any physical loop is configured or a network loop is present on the module. |
xos0064010 | The command show port buffer displays an incorrect port range for 100G I/O modules. |
xos0064201 | On BlackDiamond X8 chassis with BDXA-40G24X modules loaded in all I/O slots, some modules may occasionally time out while booting up. |
xos0064444 | Management module crashes continuously when there is a physical loop on the front panel ports of the I/O module. |