The following issues were resolved in ExtremeXOS 31.7. Release 31.7 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, 31.5, and 31.6. For information about those fixes, see the release notes for the specific release.
Release 31.7 also includes fixes for issues found in Switch Engine 31.6. Release 31.6 was the first version of Switch Engine.
Defect Number | Description |
---|---|
General | |
EXOS-29799 | A rtmgr process may end unexpectedly after running the disabling/enabling bgp command. |
EXOS-30432 | Missing error details in the printed summitCardGetMaxPhyTemp log. |
EXOS-30488 | If more than 10 optics are inserted into an ExtremeSwitching X465, the switch doesn't recognize a some optics after a reboot. |
EXOS-31064 | The switch is rebooting due to a process “OSPF” crash. |
EXOS-31159 | Unable to authenticate ExtremeXOS switches against Amazon's TACACS+ server. |
EXOS-31200 | Need to remove the extra padding added for VLAN. |
EXOS-31244 | The t1 and t4 timestamps used to calculate the delay are not displayed in the EMS logs. |
EXOS-31274 | Edge-Safeguard Disables an MLAG port when the MLAG device reboots, with no signs of a loop. |
EXOS-31285 | A Nettools process crash occurs while processing the SNMP get request of the MIB icmpMsgStatsTable. |
EXOS-31311 | Need to remove extra space between the trailing “>” of the PRI part and the Timestamp. |
EXOS-31360 | Process FDB crashes when the switch receives SNMP walk for the MIB extremeFdbPermFdbTable. |
EXOS-31368 | The configuration configure elrp-client disable-ports is lost after a switch reboot. |
EXOS-31374 | An MSPD process crash occurs while processing packets of higher length. |
EXOS-31421 | BGP encrypted password displays in plain text in an error message. |
EXOS-31475 | ExtremeSwitching 5420 and 5520 do not bring up the port at 100 MB speed with 10060 or 10060H optics. |
EXOS-31488 | The SSH status occasionally becomes invalid after a switch reboot. |
EXOS-31509 | 10504 transceivers (SFP28/25G/10km) may not be configured for proper 25G operation. |
EXOS-31539 | STP show commands need to be added in show tech. |
ACL | |
EXOS-30569 | When an internal system ACL fails to install, the failure is noted as an Information Severity instead of an Error Severity. |
ExtremeSwitching X440-G2 Series Switches | |
EXOS-30482 | A process policy signal 6 crash occurs in ExtremeSwitching X440-G2 Series switches. |
ExtremeSwitching X590 Series Switches | |
EXOS-31136 | 100G QSFP28 Direct Attach Cables are reporting a partition mismatch in ExtremeXOS despite having the correct partition (1x100G). |
Extended Edge Switching | |
EXOS-31210 | VPEX rings did not recover after rebooting a Controlling Bridge. |
MLAG | |
EXOS-31049 | FDB was not expired after moving the MAC via an IPARP packet in one of the MLAG ports. |
Netlogin | |
EXOS-31180 | A Netlogin process crash with signal 6 occurs while writing a file descriptor to the variable. |
SummitStack | |
EXOS-31406 | Backup SummitStack slots suddenly reboot after approximately 1,382 days of uptime. |