Resolved Issues in ExtremeXOS and Switch Engine 31.7.1-Patch1-56

The following issues were resolved in ExtremeXOS 31.7.1-Patch1-56. Release 31.7.1-Patch1-56 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, 31.5, 31.6, and 31.7. For information about those fixes, see the release notes for the specific release.

Release 31.7 also includes fixes for issues found in Switch Engine 31.6. Release 31.6 was the first version of Switch Engine.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 31.7.1-Patch1-56
Defect Number Description
General
EXOS-32095 Netlogin web-base URL redirection does not work when HTTP is disabled and HTTPS is enabled.
EXOS-32104 When all the fans are removed and inserted, the status of all fans display the message "Operational at 0 RPM".
EXOS-32172 Egress rate-limit does not work if max-burst-size is not specified
EXOS-32194 An ACL process crash occurs when adding an l2pt profile in VPLS.
EXOS-32202 The outer tag was removed when sending LLDP frames over L2PT.
EXOS-32204 SNMP trap gets the wrong key after a switch restart.
EXOS-32213 Process bcmASYNC crashes with signal 6 when the number of adjacencies exceeds the hardware limit.
EXOS-32280 L3 Remote Mirror is not working when configured to capture packets on the VLAN interface.
EXOS-32301 The switch sends overheat condition as an SNMPv1 trap despite a MIB files definition of SNMPV2.
EXOS-32328 HTTPS Chalet login failure with the message soap error session failed when attempting to log in via the same tab.
EXOS-32466 SLPP configurations are removed from the port but retained in the configuration when disabling the sharing on the port.
EXOS-32467 XMC or XIQ Site Engine raises an alarm if a file named EXTRTEST exists with the TFTP server.
EXOS-32468 ARP packets are not sent via the Standby slot when starting the stack with ports disabled.
EXOS-32475 A PIM L3 cache miss occurs in ExtremeXOS FHR switches when the RP switch is from a different vendor.
EXOS-32495 VPEX process crashes with signal 11, leading to a switch restart.
ExtremeSwitching 5520 Series Switches
EXOS-32471 An HAL error log occurs when upgrading an ExtremeSwitching 5520 with a 10504 Gbic.