The following issues were resolved in ExtremeXOS 22.2. ExtremeXOS 22.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, and ExtremeXOS 22.1. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
Summit Family | |
xos0065571 | Ping fails over L3VPN tunnel when the corresponding ARPs are in Layer 3 hardware hash table as "Extended View". Affects Summit X450-G2, X670-G2, and X770 platforms. |
ExtremeSwitching X440-G2 Series Switches | |
xos0064712 | The etsysCosIrlPortTypeEligiblePorts MIB shows no eligible ports for IRLs. Extreme Management Center reads this MIB to determine eligible support. Therefore, IRLs configured through Extreme Management Center do not get enforced. |
xos0064801 | In ExtremeSwitching X440-G2 series switches, the output of the show temperature command displays incorrect value. |
xos0064964 | Misleading fan failure may be reported on Summit X440-G2-12t and X440-G2-12p switches due to internal fans running at 0 RPM. Fans in these models may operate at 0 RPM if the system temperature is maintained without running the fans. This is normal operation. |
xos0066461 | Adding VLANs to a port untagged using an SNMP set shows as untagged in the show configuration vlan command. |
Summit X450-G2 Series Switches | |
xos0060461 | Need command option for iBGP and eBGP protocolS under the configure iproute ipv6 priority command. |
Summit X460-G2 Series Switches | |
xos0057796 | Power is momentarily denied to ports when a redundant PSU is inserted. |
xos0064795 | With a 4-node ERPS subring topology with no virtual channel, after link failure between two interconnect nodes, ring re-convergence, and then link restoration, traffic loss occurs for over 5 minutes. |
xos0065060 | Traffic convergence time is excessive during failover (by indirect link failure between two MPLS LDP peers) with two routes learned through MPLS. |
xos0065104 | FDB is not removed from software after ageing period. |
xos0065845 | Traffic drops between the CVID configured ports in the VPLS service VMAN when CEP egress filtering is enabled. |
xos0066140 | RSTP BPDU is not transmitted even though STP state is in forwarding mode when loop-protect is enabled. |
ExtremeSwitching X620 Series Switches | |
xos0062890 | On Summit X620 series switches, 100 mbps SFPs (100FX, FX/LX, BASET) fail to link on reboot. |
xos0065079 | ExtremeSwitching X620 series switches show external PSU as always powered off. |
xos0065920 | Link status goes to Ready state on port with 10/100/1000BASE-T optics after multiple reboots. |
Summit X670-G2 Series Switches | |
xos0064568 | After slot reboot, traffic drop occurs on VPLS service VLAN LAG port. |
xos0064965 | When fan tray-1 is empty, other fan trays display a failed status. |
xos0065150 | When LAG ports are added to VPLS, LACP flap occurs after rebooting the slots in the stack. |
xos0065243 | On MLAG-configured switches with 160 or greater VXLAN segments, after a reboot of one of the MLAG peer switches, one or two VXLAN segments are not re-created though the tenant VLAN exists. |
xos0065724 | Traceroute fails when the intermediate router is a VRRP gateway. |
xos0065962 | OTM process ends unexpectedly when creating, and then deleting, 700 VXLAN segments. |
Summit X770 Series Switches | |
xos0064590 | Port partitioning configuration is lost after a reboot if there is no physical cable attached to the partitioned port. |
SummitStack | |
xos0060485 | MPLS process ends unexpectedly with signal 11 when changing the LSR ID. |
xos0064758 | In SummitStacks, when doing SNMP walk for LLDP MIB, port number does not represent the ifIndex or dot1dBasePort number. |
xos0065115 | In a stack with a backup, configuring a RADIUS(or RADIUS-accounting) server (primary or secondary) using a hostname causes the backup to reset when trying to resolve the hostname using DNS. |
xos0065255 | RADIUS server hostname configuration is not pushed to backup in stack after failover. |
xos0065387 | SNMP times out while when saving on an eight-node stack of Summit X440 series switches. |
xos0065756 | In SummitStacks, alternate IP address is used for external communication even though a Management IP address is configured. |
xos0066085 | Restart of some processes does not work properly when the standby slot has a lower license level. |
xos0066104 | In SummitStacks, memory leak occurs in backup slot when configuring LLDP to advertise power-via-mdi with classification. |
xos0066423 | In Summit stack, with Policy re-authentication and continuous MAC move scenarios, ACL delete request is failing in backup node. |
General | |
xos0063551 | SNMP polling on CFM segment frame-delay statistics returns incorrect values. |
xos0064722 | Setting a CoS component IRL or IUB to none (0) in Policy manager (Extreme Management Center) should imply an interpretation by the platform of rate equivalent to "unlimited." However when "0" or "none" is enforced to a Summit Ingmeter this does not mean unlimited, but instead a literal 0 rate. |
xos0065210 | With account lockout feature configured, an appropriate log message is not generated when users are locked out after three unsuccessful login attempts. |
xos0065215 | Slow xmld process memory leak occurs when EPIC center polling the switch. |
xos0065218 | DHCP binding restoration fails if the file name is configured with directory name. |
xos0065226 | When Extreme Network switch is acting as a DHCP server, the default-gateway address is sent as the DNS server address even if it has been configured on the switch. |
xos0065313 | Need Idle-timeout feature added to Chalet. |
xos0065321 | With SSH session, source address information is not sent to TACACs accounting server. |
xos0065525 | Need modifications in port ID TLV. Device ID TLV is sent in CDP messages. |
xos0065615 | Local multicast traffic is not egressing using a newly added member port in a LAG. |
xos0065661 | IPMC error messages occur when multicast cache entries are created/deleted for sub-VLAN, when sub-VLAN and super-VLAN belong to different virtual routers. |
xos0065977 | Random Nettools process ends unexpectedly with Signal 5 when router discovery and DNS is enabled. |
xos0066059 | CLI cursor jumping when word wrapping when using SSH session. |
xos0066156 | Switch reboots unexpectedly due to memory leak in dot1ag process. |
xos0066345 | XMLC process ends unexpectedly with signal 6 when sending XML notification to Ridgeline server. |
xos0066386 | The show configuration commands stops responding and produces an error when there is a loop in the network. |
xos0066472 | Executing the debug hal show compact-flash command returns kernel mismatch error. |
xos0066806 | PIM checkpointing loop occurs between two switches that have two ISCs over two VRs. |
xos0066891 | Packets are being forwarded without a tag after rebooting when PSTAG configured. This issue occurs when VLANs are configured with VID as "1". |
xos0066926 | Errors occur when configuring OpenFlow in passive mode. |
xos0066950 | Hash collision error messages may appear when there is contention for the L3
Hash table:
<Warn:Kern.IPv4Adj.Warning> vrId 0 adj 0x00000002 Error finding adjacency when deleting hash collision. |
xos0061317 | Switch reboots unexpectedly when enabling FIP snooping. |
xos0061948 | VLAN statistics do not work after modifying the shared group. |
xos0064734 | Auto-move of ports from one VLAN to another is not working when ports are added using the all keyword. |
xos0064859 | In SummitStack, gPTP process ends unexpectedly during bootup if AVB license was enabled on any of the stack nodes. |
xos0064975 | Ejecting a memory card using the eject memorycard command changes the switch configuration so that it does not save core dump files to memory or a removable storage device. |
xos0065261 | Traffic loss occurs in one VLAN when another VLAN with a loop causes significant congestion. |
xos0065677 | With harmless ECC single-bit errors, Kernel error logs "ERROR PBANK_LSB". |
xos0066006 | When ICMP redirect is received and the new gateway ARP is not resolved, the redirect route becomes valid and is used. This results in traffic being dropped. This problem is more apparent when the redirection happens to a host on a different subnet because ExtremeXOS enables IP ARP checking by default. |
xos0066462 | Copying a file into cfg directory results in a crash. |
ACL | |
xos0065056 | After applying meter to multiple VLANs, switch stops responding after executing show access-list meter vlan. |
BGP | |
xos0052432 | Need provision for advertising/receiving unique local IPv6 unicast address (ULA) using BGP protocol. |
xos0058666 | BGP multicast routes are not displayed in routing table when origin is specified. |
xos0063959 | BGP routes become unfeasible when default routes are advertised through OSPF or BGP. |
DHCP/BOOTP | |
xos0054151 | DHCP server configuration is lost after reboot when IP DAD is on. |
xos0064138 | Client identifier option length in DHCPv6 solicit packet is 16 instead of 14 with Link layer address padded with zeroes. |
xos0064727 |
On DHCPv6 clients, sometimes the IPv6 address is not removed even after disabling the client, and after rebooting, the IPv6 address is saved and this causes the client to go into a stopped state with the following error message appearing: <Erro:vlan.AddIPAddrFail> Failed to add IP addr 8001::4aa6:dd38:9b32:e7b/128 from DHCPv6 to VLAN client, DHCPv6 configured IPv6 address already exist on interface client |
ELRP | |
xos0064923 | When a remote loop is detected by ELRP (ingress and egress port of loop detection is the same) an excessive number of log messages occur. |
ERPS | |
xos0065805 | Constant flush happens in ERPS non-revertive mode when the port being blocked is non-RPL. |
xos0066489 | Loop occurs in ERPSv2 setup after rebooting one of the interconnecting nodes. |
xos0066490 | ERPS in non-RPL nodes remains in pending state after rebooting interconnection node. |
IGMP | |
xos0065109 | Packets with DMAC as multicast MAC and DIP as unicast IP are software forwarded when IGMP filter mode is per-VLAN. |
LACP/LAG | |
xos0066029 | In Summit X460-G2 stacks, LACP keeps flapping due to forwarding one LACP PDU to another group. |
LLDP | |
xos0064841 | LLDP stops advertising VLAN information on port after enabling LAG. |
MLAG | |
xos0066323 | When MLAG is configured with alternate path and ISC link goes down, a peer down log message is not generated. |
xos0066325 | When MLAG is configured with alternate path and primary path goes down, SNMP trap for ExtremeMlagPeerDown object is not generated. |
OpenFlow | |
xos0065159 | OpenFlow process ends unexpectedly with signal 11 when OpenFlow controller installs LLDP flow. |
Optics | |
xos0065764 | Link status goes to Ready state on port with 10/100/1000BASE-T optics after multiple reboots. |
OSPFv2 | |
xos0065830 | After port flaps, OSPF-learned routes are not present in kernel database. |
xos0066804 | Routes learned from OSPF are lost after multiple port flaps occur. |
Policy | |
xos0060930 | When ONEPolicy is enabled and you reach the configured maximum number of authenticated sessions, sessions continue to attempt to authenticate, and then terminate if successful. |
xos0064809 | If policy is already enabled a second issuing of the command enable policy produces an error "ERROR: Hardware resources were not reserved for Policy." and policy is disabled. |
xos0065256 | Enabling policy with large number of rules may result in timeout during slice reservation. When this happens policy fails to enable properly and could trigger high CPU utilization in policy/HAL for an extended period. |
xos0065552 | RADIUS-accounting request packet shows incorrect reason for client termination. |
xos0064996 | In Summit X460-G2 with X450-G2 stacks, ACL slices are not reserved for policy after changing resource-profile from default to more-mac-no-ipv6 and more-ipv4-no-ipv6. This issue only occurs in mixed mode stack and does not occur in X450-G2, X460-G2, and X670-G2 standalone switches and homogeneous stacks of X460-G2 and X460-G2). |
xos0065081 | Policy authenticated users on a port may cause an incorrect vlan association with subsequent unauthenticated users, which could affect web-based authentication. |
RSVP-TE/FRR | |
xos0065987 | Service port FDB entries are learned on physical port of Network VLAN in provider switch. |
Security | |
xos0062037 | DHCP snooping entry gets programmed without client port number. |
xos0062758 | With policy enabled, client authenticated using NetLogin is not getting aged out when reauthentication is configured. |
xos0063509 | Controlling trap behavior is not working in NetLogin. |
xos0063806 | After establishing SSH session with switch for some time, SSH login fails and the command show management becomes unresponsive. |
xos0064874 | Tagged frames should be processed for authentication with NetLogin and policy enabled. |
xos0064904 | With a frequent re-authentication period set (>= 30 seconds), NetLogin process leaks memory. |
xos0065648 | When a MAC address moves from a NetLogin-enabled port (mac-vlan mode) to a
non-NetLogin-enabled port, the VLAN_MAC table can become full resulting in the
following message:
&ltWarn:HAL.FDB.MacVlanAddFail&gt MAC-based VLAN entry 78:7E:61:A1:DC:DC vlan 2600 addition to port 22 failed, Table full |
xos0065712 | When repeated login and logout is performed using SSH-PKI (SSH login using certificates) for about two days from eight terminals, memory leak occurs. |
xos0065897 | When continuous SSH attempts are made to a switch, exsshd process ends unexpectedly with signal 6. |
xos0066027 | After downloading certificates, the commands show ssl trusted-ca and show ssl ocsp-signature-ca fail to show any output. However, PKI validation that makes use of these certificates works. |
xos0066626 | NetLogin process ends unexpectedly with signal 11 when RADIUS accept packet contains MS-ipv4-remediation-servers attribute with an incorrect IP address. |
xos0066758 | SSH login fails in first attempt, but succeeds in the second attempt, during RADIUS authentication even if credentials are valid. |
xos0066770 | Memory leak occurs in aaa process when NetLogin dot1x client times out or authentication fails for the client. |
xos0066874 | AAA process is leaking memory when dot1x clients are authenticating frequently. |
xos0066982 | In NetLogin dot1x, RADIUS retries are not working properly. |
xos0062680 | Switch fails to send Radius accounting message for dot1x user after clear netlogin state port portNumber command. |
sFlow/Netflow | |
xos0065654 | Etmon process ends unexpectedly with signal 10 when packet size in sampled packet is a negative integer. |
SNMP | |
xos0065479 | Need a command option to save the state of whether or not the following traps are enabled for cfgMgmtConfigChangeTrap and cfgMgmtSaveConfigTrap. |
xos0065943 | SNMP walk for extremePortUtilizationTable returns integer value, but CLI output returns decimal value. |
STP/RSTP/MSTP | |
xos0065021 | Discarding of STP/PVST+ BPDUs in slow path occurs when STP BPDU forwarding is disabled. |
xos0066837 | When the switch is rebooted, the edge port gets blocked even though the STP domain is disabled. |
VPLS | |
xos0063424 | Source MAC address is learned on the incorrect VLAN for double-tagged packets with inner VLAN ID that is the same as the VPLS service VLAN ID. |
xos0065372 | MPLS error messages occur after disabling, and then enabling network VLANs. |
xos0066476 | MPLS label TTL is not set properly for VPLS traffic in RSVP-TE. |
VR/VRF/L3VPN | |
xos0061488 | Decompressed routes are not programmed into hardware after disabling IPv4 compression. |
xos0061489 | Compressed routes are not programmed into hardware when master route fails. |
xos0065183 | Recreating a VPN VRF with same name after deleting it produces a BGP error. |
VRRP | |
xos0061817 | VRRP fabric routing is not supported for VRRP owner address (configuring at priority 255). |
xos0064538 | Process VRRP ends unexpectedly with signal 11 after enabling VRRP between tow switches. |
XNV | |
xos0061611 | FDB entry from base VLAN is not removed after restarting XNV dynamic VLAN-enabled ports. Issue occurs when clearing FDB also. |
xos0064338 | After creating XNV dynamic VLAN with XNV enabled at MLAG port (and its corresponding ISC Port), FDB entry for tracked MAC is learned on base VLAN instead of dynamic VLAN causing flooding and FDB issues. |