configure inline-power label ports

configure inline-power label string ports port_list

Description

Lets you create your own label for a specified This command is available on the ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, and X620 series switches. port or group of PoE ports.

Syntax Description

string Specifies a name up to 15 characters in length to identify the specified power port(s).
port_list Specifies one or more ports or slots and ports.

Default

No label.

Usage Guidelines

Use the show inline-power configuration ports command, as shown in the following example, to display inline power configuration information, including the label (if any) for each port:

show inline-power configuration port 3:1-10

Following is sample output from this command on a SummitStack:

Port   Config   Operator Limit   Priority   Label
3:1    Enabled     16000 mW      Low        finance
3:2    Enabled     15000 mW      Low        finance
3:3    Enabled     15000 mW      Low
3:4    Enabled     15000 mW      Low
3:5    Enabled     15000 mW      Low
3:6    Enabled     15000 mW      Low        marketing
3:7    Enabled     15000 mW      Low        marketing
3:8    Enabled     15000 mW      Low        marketing
3:9    Enabled     15000 mW      Low
3:10   Enabled     15000 mW      Low

Example

The following command assigns the name “alpha-test_1” to port 1 on slot 4:

config inline-power label alpha-test_1 ports 4:1

History

This command was first available in ExtremeXOS 11.1.

Platform Availability

This command is available on: