The following issues were resolved in ExtremeXOS 16.2.3-Patch1-14. ExtremeXOS 16.2.3-Patch1-14 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, and ExtremeXOS 16.2.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0068323 | In ExtremeXOS Python scripting, the argument sent to the command Exsh.clicmd is replicated 24 times. |
xos0068325 | Custom web page does not display image in Netlogin web-based authentication when IP address of Netlogin VLAN is used to login from browser. |
xos0068767 | Trap receiver configuration is not saved in ExtremeXOS when configured from Extreme Management Center. |
xos0068911 | After enabling STP auto-bind on a VLAN, removing all ports from the VLAN, and then adding them back, displays STP tag as "(none)" in the show ports information detail command. |
xos0069070 | The process BCMAsync stops processing with scaled route/ARP entries in hash table. |
xos0069220 | Users can access Chalet by easily guessing the login session ID created by an existing session. |
xos0067280 | Uploading a file using SFTP creates a read-only file on the switch. |
xos0068785 | L2PT packets fail to switch over to backup path during failover. |
xos0068057 | HAL process ends unexpectedly with signal 6 and 11 when deleting and re-adding subscriber VLAN from private VLAN. |
xos0067459 | HA process ends unexpectedly with signal 11 while sending L3 known traffic over PVLAN configuration. |
xos0057140 | Transceiver information for 40G Q+SR4 optic module shows invalid power and threshold values. |
xos0066726 | Hal process ends unexpectedly with signal 11 when trying to add a port to the network VLAN of PVLAN. |
SummitStack | |
xos0068500 | HAL timeout occurs while rebooting the stack using the command reboot stack-topology. |
BlackDiamond X8 Series Switches | |
xos0063830 |
On BlackDiamond X8 series switches, fan tray and FM LEDs behave incorrectly when fan tray is hot swapped. BDX8. |
xos0067644 | On BlackDiamond X8 series switches, the I/O module status LED shows the incorrect status when MM-A module is removed from the chassis. |