The following issues were resolved in ExtremeXOS 16.2.5-Patch1-7. ExtremeXOS 16.2.5-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, ExtremeXOS 16.2.3, ExtremeXOS 16.2.4, and ExtremeXOS 16.2.5. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0071584 | The cookie field in the OpenFlow packet in-message is always set to incorrect value 0x0000000000000000. |
xos0072913 | After timing out on Dot1x supplicant expiry timer, switch does not respond to EAPOL start packets received from supplicants. |
xos0072979 | After rebooting the switch or restarting the Dot1x supplicant, Dot1x state machine remains in connecting state, and clients are not authenticated if MAC and Dot1x are enabled on the same port. |
xos0073070 | The limit-learning feature is not working as expected in MAC Move/LOOP scenarios. |
xos0073143 | After retrieving VLAN statistics through SNMP or CLI in a certain sequence, switch stops responding to VLAN related SNMP polling and show commands. |
xos0073224 | In Policy mode, dynamically added ports on a VLAN for a MAC session are not removed from the VLAN even though the MAC session is overwritten by a Dot1x session. |
xos0070532 | ACL smart refreshed does not work after change in the packet resolution. |
xos0071071 | MLAG ports do not come up after running fail-over with alternate MLAG IP configuration. |
xos0072517 | Traffic is dropped over VPLS when the service VMAN is deleted and then added multiple times with sharing enabled on access. |
xos0072581 | In VRRP IPv6 environment, router advertisement with link-local IPv6 interface address causes host connectivity issues. |
xos0072647 | The polMgr process ends unexpectedly on backup MSM after executing refresh policy, and then unconfigure policy. |
xos0072940 | Port does not come up when connected with 2-pair (1,2,3,6 wire connected) Ethernet cable. |
xos0073155 | Two IPV6 gateways appear on the Windows computer (host) after disabling/enabling the VRRP master VLAN port. |
xos0073226 | EDP process ends unexpectedly when processing CDP packets having a device ID that is null. |
xos0073248 | Ping fails between switches when the connected port is removed from the VMAN. |
xos0073251 | Snmpmaster process ends unexpectedly in rare cases when packets received at an application fail. |
xos0073279 | Port does not come up when Amphenol DAC cable is used. |
xos0073376 | ACL smart refresh is not working as expected for source address (0.0.0.0/0) match condition. |
xos0073378 | With FIPS mode enabled, and after upgrading from ExtremeXOS 16.1, Exsshd process ends unexpectedly with signal 11 when attempting to log on to SSH. |
xos0073383 | Memory leak occurs on HAL when port is removed, and then added back to a LAG. |
xos0073394 | FDB is not check-pointed correctly with W-MLAG configuration. |
xos0073320 | Need new commands to enable/disable external Python script execution that is enabled by default. |
BlackDiamond 8000 Series Switches | |
xos0065442 | Unable to upgrade firmware on specific I/O modules even when using the install firmware force command. |
Summit X670-G2 Series Switches | |
xos0073117 | On Summit X670-G2 series switches after an ExtremeXOS upgrade, the error "Deferred L2 notification code out of sync unit 0" appears in show log output. |