The following issues were resolved in ExtremeXOS 21.1.3-Patch1-7. ExtremeXOS 21.1.3-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, ExtremeXOS 21.1.2, and ExtremeXOS 21.1.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0062758 | With policy enabled, client authenticated using NetLogin is not getting aged out when reauthentication is configured. |
xos0065527 | Edge safeguard configuration gets lost when ports are removed and added back to default VLAN. |
xos0066477 | Creating a VLAN starting with "vr" causes syntax recognition problems with the show iparp vr command. |
xos0066557 | Kernel crash occurs after removing a subVLAN from one VR and adding the same subVLAN in another VR. |
xos0066932 | Actual/configured sFlow sample rates are different after reconfiguring. |
xos0066984 | RADIUS-accounting request packet shows incorrect account-terminate reason for user logout from SSH/Telnet session. |
xos0066996 | ESRP does not update the neighbor state properly while becoming master from neutral state. |
xos0067002 | UPM status is "fail" if UPM profile has <i>save configuration as-script</i> as the last command. |
xos0067079 | ACL installation for the policy authenticated client is failing when diffserv replacement and meter configuration is present in the switch. |
xos0067108 | Packets received on STP blocked ports gets forwarded to other STP port when netlogin & onePolicy is enabled with authentication mode optional. |
xos0067323 | FDBs are learned on incorrect VPLS peer on PE switches after include/exclude dot1q tag in P switch. |
xos0067325 | After recovering from multiple link failures, ERPS incorrectly keeps both the ring links in blocked state. |
xos0067335 | Memory leak occurs in VMT process when it is enabled on the port. |
xos0067463 | Traffic does not distribute across LSPs and LAG after enabling L2VPN sharing feature. |
xos0067506 | A few VRRP instances remain in dual master state if VRRP state changes for several VLANs in the same VRID within a short time period. |
xos0067820 | ExtremeXOS refuses connections with usernames starting with letters h, i ,j, k, p, q, r, and s using SOAP/XML. |
xos0067887 | Switch reboots unexpectedly when there are continuous SSH attempts and those attempts are rejected with access-profile. |
xos0067912 | The command show port protocol filter displays the "Error: Configuration reply is too big" in output. |
xos0068209 | PIM process ends unexpectedly with signal 11. |
xos0066941 | Add a support for USB Zero Touch Provisioning. |
xos0067583 | Add support to configure ping success for VRRP track-ping. |
xos0067973 | After run failover, IDM kerberos system ACLAs are missing for some users in new master. |
xos0059947 | Spurious log messages occur in the hardware while deleting tenant VLAN in the switch. |
xos0065930 | ACLCBFUNC log occurs after associating a policy that has CLEAR-flow and network-zone configuration. |
xos0066883 | Process HAL ends unexpectedly with signal 11 on restarting all ports with basic VXLAN configuration. |
xos0066921 | ARP fails to resolve for some hosts. |
xos0067084 | FDB is not learned over pseudowire after disabling, and then enabling, learning on network VLAN ports. |
xos0068099 | After rebooting the switch, BGP neighbor configuration is lost when a peer group is configured. |
xos0067087 | CFM LMR/DMR packets are sent with dot1p value 0. |
xos0065571 | Ping fails over L3VPN tunnel when the corresponding ARPs are in Layer 3 hardware hash table as "Extended View". Affects Summit X450-G2, X670-G2, and X770 platforms. |
xos0060343 | On Summit X670v stack, configuration file replication on standby nodes times out after second or third failover. |
xos0067106 | In dot1x authorization, service unavailable vlan port is re-authenticated in every authorization causing blocked port. |
xos0063669 |
Erro:RtMgr.Client.ReplyTimeOut messages appear after run failover/reboot: <Warn:EPM.hello_rate> Slot-2: Received hellos from process rtmgr 2 more often then expected 3 <Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (ADDUPDRTE). <Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (RTEGET). |
xos0067446 | "ACL filter update failed" error occurs when modifying the code point value. |
xos0066963 | Jumbo frame is disabled on master port after rebooting when ports are partitioned. |
xos0062668 | MIB compilation issues occur with VLAN MIB when using mgsoft. |
xos0066697 | Delay occurs in password prompt appearing when trying to establish SSH connection. |
xos0064870 | Slots fail sometimes when applying PVLAN and STP configuration. |
Summit X440-G2 Series Switches | |
xos0066945 | On Summit X440-G2 series switches, 10G ports are not coming up with 5-meter passive copper cable when connected to ExtremeSwitching X620-16X. |
Summit X670-G2 Series Switches | |
xos0066844 | Port with copper SFP inserted appears as active even if it is administratively disabled. |
SummitStack | |
xos0058499 | In SummitStack, the snmpEngine values are maintained in each node separately instead of a single value, which is causing different values on each failover. |