The following issues were resolved in ExtremeXOS 21.1.2-Patch1-2. ExtremeXOS 21.1.2-Patch1-2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, and ExtremeXOS 21.1.2. For information about those fixes, see the release notes for the specific release.
Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 21.1.2-Patch1-2
CR Number | Description |
---|---|
General | |
xos0065393 | Memory leak occurs in HAL process after FDB entries age out. |
xos0065519 | Loops may occur in network after the performing the following
specific sequence:
|
xos0054151 | DHCP server configuration is lost after reboot when IP DAD is on. |
xos0061948 | VLAN statistics not working after modifying the shared group. |
xos0062722 | NetLogin does not work after a port moved to translation VLAN expires. |
xos0063194 | Dot1x authentication fails after rebooting the client when it is connected via IP phone. |
xos0063326 | Need to reduce the severity of "BGP resource full" message from Error to Info. |
xos0063424 | Source MAC address is learned on the incorrect VLAN for double-tagged packets with inner VLAN ID that is the same as the VPLS service VLAN ID. |
xos0063509 | Controlling trap behavior is not working in NetLogin. |
xos0064023 | L3 table full log appears because of false resource full triggered by link flaps. |
xos0064501 | Lacking forbidden VLAN concept in OnePolicy feature. |
xos0064706 | Cannot use SSH client after using "vi script.py" or "load script script". |
xos0064707 | Error message from the load script command does not indicate that Python is a supported script language. |
xos0064841 | LLDP stops advertising VLAN information on port after enabling LAG. |
xos0064889 | Layer 3 traffic through an MLAG peer in a failed state is not forwarded when there is a state change in the EAPS ring where this MLAG peer is a transit node. |
xos0064904 | With a frequent re-authentication period set (>= 30 seconds), NetLogin process leaks memory. |
xos0064984 | Kernel oops occurs randomly when continuous SSH connection attempts are made to the switch. |
xos0065005 | Rtmgr process ends unexpectedly some times during frequent route transitions with Multicast, MPLS, and OSPF routes. |
xos0065056 | After applying meter to multiple VLANs, switch stops responding after executing show access-list meter vlan. |
xos0065104 | FDB is not removed from software after ageing period. |
xos0065109 | Packets with DMAC as multicast MAC and DIP as unicast IP are software forwarded when IGMP filter mode is per-VLAN. |
xos0065110 | Creating one VLAN starting with "vr" causes the show iproute vr vr-mgmt command to not recognize "vr-mgmt in the syntax. |
xos0065120 | Configuring port display-string with special characters causes page loading issues on Chalet. |
xos0065197 | Rtmgr process ends unexpectedly with signal 11 after issuing restart ports all command in peer switch with BGP enabled. |
xos0065215 | Slow xmld process memory leak occurs when EPIC center polling the switch. |
xos0065218 | DHCP binding restoration fails if file name is configured with directory name. |
xos0065226 | When Extreme Network switch is acting as a DHCP server, the default-gateway address is sent as the DNS server address even if it has been configured on the switch. |
xos0065261 | Traffic loss occurs in one VLAN when another VLAN with a loop causes significant congestion. |
xos0065301 | FDB entries are not programmed in the hardware as programmed in the software. |
xos0065308 | Kernel crash occurs when unconfiguring switch with maximum ACL rules. |
xos0065322 | IPv6 neighbor-discovery max_pending_entries configuration for USER-VR does not appear in output of show configuration command and is lost after reboot. |
xos0065344 | The output of the show vid command shows flag status incorrectly. |
xos0065661 | IPMC error messages occur when multicast cache entries are created/deleted for sub-VLAN, when sub-VLAN and super-VLAN belong to different virtual routers. |
xos0065677 | With harmless ECC single-bit errors, Kernel error logs "ERROR PBANK_LSB". |
xos0065542 | Kernel crash occurs when rebooting the switch with a physical loop. |
xos0065871 | LLDP process ends unexpectedly with signal 6 when doing SNMP walk for lldpXMedLocLocationTable. |
ExtremeSwitching X440-G2 Series Switches | |
xos0064801 | In ExtremeSwitching X44-0G2 series switches, the output of the <i>show temperature</i> command displays incorrect value.. |
ExtremeSwitching X620 Series Switches | |
xos0065079 | ExtremeSwitching X620 series switches show external PSU as always powered off. |
SummitStack | |
xos0065157 | In SummitStacks with remote mirroring configurations, the remote-tag is not added for software-forwarded packets. |
xos0064758 | In SummitStacks, when doing SNMP walk for LLDP MIB, port number does not represent the ifIndex or dot1dBasePort number. |
xos0065088 | With broadcast traffic flooded across the slots, the standby node stays in rebooting state after consecutive master failovers by cycling the power off, and then on. |
xos0065071 | When backup node is in failed state due to license mismatch, master node CPU utilization spikes to 100% and stops responding. |