The following issues were resolved in ExtremeXOS 21.1.2-Patch1-2. ExtremeXOS 21.1.2-Patch1-2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, and ExtremeXOS 21.1.2. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0065393 | Memory leak occurs in HAL process after FDB entries age out. |
xos0065519 | Loops may occur in network after the performing the following
specific sequence:
|
xos0054151 | DHCP server configuration is lost after reboot when IP DAD is on. |
xos0061948 | VLAN statistics not working after modifying the shared group. |
xos0062722 | NetLogin does not work after a port moved to translation VLAN expires. |
xos0063194 | Dot1x authentication fails after rebooting the client when it is connected via IP phone. |
xos0063326 | Need to reduce the severity of "BGP resource full" message from Error to Info. |
xos0063424 | Source MAC address is learned on the incorrect VLAN for double-tagged packets with inner VLAN ID that is the same as the VPLS service VLAN ID. |
xos0063509 | Controlling trap behavior is not working in NetLogin. |
xos0064023 | L3 table full log appears because of false resource full triggered by link flaps. |
xos0064501 | Lacking forbidden VLAN concept in OnePolicy feature. |
xos0064706 | Cannot use SSH client after using "vi script.py" or "load script script". |
xos0064707 | Error message from the load script command does not indicate that Python is a supported script language. |
xos0064841 | LLDP stops advertising VLAN information on port after enabling LAG. |
xos0064889 | Layer 3 traffic through an MLAG peer in a failed state is not forwarded when there is a state change in the EAPS ring where this MLAG peer is a transit node. |
xos0064904 | With a frequent re-authentication period set (>= 30 seconds), NetLogin process leaks memory. |
xos0064984 | Kernel oops occurs randomly when continuous SSH connection attempts are made to the switch. |
xos0065005 | Rtmgr process ends unexpectedly some times during frequent route transitions with Multicast, MPLS, and OSPF routes. |
xos0065056 | After applying meter to multiple VLANs, switch stops responding after executing show access-list meter vlan. |
xos0065104 | FDB is not removed from software after ageing period. |
xos0065109 | Packets with DMAC as multicast MAC and DIP as unicast IP are software forwarded when IGMP filter mode is per-VLAN. |
xos0065110 | Creating one VLAN starting with "vr" causes the show iproute vr vr-mgmt command to not recognize "vr-mgmt in the syntax. |
xos0065120 | Configuring port display-string with special characters causes page loading issues on Chalet. |
xos0065197 | Rtmgr process ends unexpectedly with signal 11 after issuing restart ports all command in peer switch with BGP enabled. |
xos0065215 | Slow xmld process memory leak occurs when EPIC center polling the switch. |
xos0065218 | DHCP binding restoration fails if file name is configured with directory name. |
xos0065226 | When Extreme Network switch is acting as a DHCP server, the default-gateway address is sent as the DNS server address even if it has been configured on the switch. |
xos0065261 | Traffic loss occurs in one VLAN when another VLAN with a loop causes significant congestion. |
xos0065301 | FDB entries are not programmed in the hardware as programmed in the software. |
xos0065308 | Kernel crash occurs when unconfiguring switch with maximum ACL rules. |
xos0065322 | IPv6 neighbor-discovery max_pending_entries configuration for USER-VR does not appear in output of show configuration command and is lost after reboot. |
xos0065344 | The output of the show vid command shows flag status incorrectly. |
xos0065661 | IPMC error messages occur when multicast cache entries are created/deleted for sub-VLAN, when sub-VLAN and super-VLAN belong to different virtual routers. |
xos0065677 | With harmless ECC single-bit errors, Kernel error logs "ERROR PBANK_LSB". |
xos0065542 | Kernel crash occurs when rebooting the switch with a physical loop. |
xos0065871 | LLDP process ends unexpectedly with signal 6 when doing SNMP walk for lldpXMedLocLocationTable. |
ExtremeSwitching X440-G2 Series Switches | |
xos0064801 | In ExtremeSwitching X44-0G2 series switches, the output of the <i>show temperature</i> command displays incorrect value.. |
ExtremeSwitching X620 Series Switches | |
xos0065079 | ExtremeSwitching X620 series switches show external PSU as always powered off. |
SummitStack | |
xos0065157 | In SummitStacks with remote mirroring configurations, the remote-tag is not added for software-forwarded packets. |
xos0064758 | In SummitStacks, when doing SNMP walk for LLDP MIB, port number does not represent the ifIndex or dot1dBasePort number. |
xos0065088 | With broadcast traffic flooded across the slots, the standby node stays in rebooting state after consecutive master failovers by cycling the power off, and then on. |
xos0065071 | When backup node is in failed state due to license mismatch, master node CPU utilization spikes to 100% and stops responding. |