The following issues were resolved in ExtremeXOS 21.1.4-Patch1-3. ExtremeXOS 21.1.4-Patch1-3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, ExtremeXOS 21.1.2, ExtremeXOS 21.1.3, and ExtremeXOS 21.1.4. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0057140 | Transceiver information for 40G Q+SR4 optic module shows invalid power and threshold values. |
xos0065665 | Incorrect MAC address entries appear in "l2_user_entry" table. |
xos0067280 | Uploading a file using SFTP creates a read-only file on the switch. |
xos0068002 | File system check of /dev/hda8 failed error occurs during switch power cycle after “manufacture-init”. |
xos0068304 | External PSU status appears as "failed" in show power command output even though it is not present. |
xos0068687 | Multicast traffic to host randomly stops when enabling onePolicy with PVID 4095. |
xos0068767 | Trap receiver configuration is not saved in ExtremeXOS when configured from Extreme Management Center. |
xos0068785 | L2PT packets fail to switch over to backup path during failover. |
xos0068810 | SNMP walk on entPhysicalClass returns Other(1) instead of Fan(7) for fan trays. |
xos0068840 | NetLogin process ends unexpectedly with signal 11, when client sends logoff message before completing the authentication process. |
xos0068911 | After enabling STP auto-bind on a VLAN, removing all ports from the VLAN, and then adding them back, displays STP tag as "(none)" in the show ports information detail command. |
xos0069061 | Exsshd process ends unexpectedly with signal 11 during stack failover. |
xos0069070 | The process BCMAsync stops processing with scaled route/ARP entries in hash table. |
xos0069220 | Users can access Chalet by easily guessing the login session ID created by an existing session. |
xos0062256 | When auto-polarity is turned off, link comes up for straight cable rather than crossover connection. |
xos0062785 | Need a mechanism to avoid configuring static route gateway and local IP as the same. |
xos0062882 | Whole MIB compilation gets stuck at EXTREME-V2-TRAP MIB. |
xos0065300 | Kernel crash occurs when there are continuous new multicast streams with PIM SM configuration. |
xos0067587 | When running show tech-support command with user-created VRs, show configuration command does not display full configuration. |
xos0068888 | When the command show tech-support all detail is executed after running enable cli-config-logging, messages beginning with "serial unknown" appear in the log. This issue also occurs when executed from a Telnet session. |
xos0069051 | After 65,000 new FDB entries are learned, subsequent entries are continuously added and deleted. |
xos0069114 | The show configuration command output displays additional word "minutes" under "aaa" module when lockout-time-period is configured. |
xos0069150 | In the output of the show vlan command, ports can have both "!" and "*" flags set if the port is a share group port. |
xos0069180 | Cannot configure some IP security features after removing and adding ports from VLANs. |
xos0069196 | Inconsistent port learning flag appears in HAL with PVLAN and MLAG configuration. |
xos0069210 | Unable to create private VLAN with 32-character name if the first 31 characters match an existing private VLAN name. |
xos0069423 | When using Chalet to configure the sysContact and sysLocation, semicolon is not allowed. |
Summit X770 Series Switches | |
xos0069487 | HAL process ends unexpectedly with signal 6 when switch boots up with PTP configurations. |
Summit X440-G2 Series Switches | |
xos0068490 | On ExtremeSwitching X440G2-48P/48t switches, cable diagnostic script (cablediag.py) does not work. |
SummitStack | |
xos0068500 | HAL timeout occurs while rebooting the stack using the command reboot stack-topology. |
Security | |
xos0069306 | Session hijacking (CVE-2017-14332): A remote user can hijack a session on the switch web server due to the SessionIDs used by the webserver authentication service on ExtremeXOS being insufficiently random. Also, documented in xos0069140. |
xos0069140 |
The following are ExtremeXOS vulnerabilities due to scripting allowed when in FIPS
mode:
The following are additional ExtremeXOS vulnerabilities:
|
xos0069213 | Denial-of-service (CVE-2017-14328): A remote user can force the switch to reboot by sending a single, specially crafted SOAP packet to the web server. Also documented in xos0069140. |