The following issues were resolved in ExtremeXOS 21.1.5-Patch1-9. ExtremeXOS 21.1.5-Patch1-9 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0050771 | The command show access-list dynamic counters does not display the complete MAC address of VMs and it may not be possible to read the counters correctly from the output. |
xos0052723 | With L3VPN configured (also: OSPF, BGP, MPLS, LSP) and routes are being advertised and installed in the VRF routing table, after restarting process OSPF, VPN routes are not installed. |
xos0056829 | Switches do not re-send the Group Specific Query following the last_member_query_interval (1 second). |
xos0057231 | An FDB entry created by ARP with "i" flag set is not removed from the FDB table after a static entry for the same IP address is added with a different MAC value. |
xos0057269 | SNMP trap extremeIpSecurityViolation is sent with incorrect VLAN description. |
xos0057374 | Switch odometer value is reinitialized when Master Switch Fabric Module (MSM) fails to read the value. |
xos0057672 | The process rtmgr ends unexpectedly when disabling GRE tunnels. |
xos0058669 | DHCPv6 client: After changing the client identifier type, and then restarting the port, old IPv6 addresses are not released, causing the show vlan command to show multiple IPv6 addresses. |
xos0058750 | Neighbor discovery packets are duplicated in L2 VLANs when IPv6 addresses are configured for other VLANs that do not have any ports. |
xos0059942 | SSH connection ends when show commands produce lengthy output. |
xos0060092 | Fetching values using SNMP for "extremePortQosStatsTable" does not work correctly. |
xos0060643 | Commands for downloading and installing images should use active/inactive options when specifying partitions (in addition to current primary/secondary options). |
xos0061085 | Kernel oops occurs while deleting VR with enable BGP export and IPARP proxy configurations. |
xos0061173 | L2PT packets are dropped when ingress port is configured with software learning. |
xos0061198 | Disabling VPN-VRF affects traffic on another VPN-VRF. |
xos0061219 | Parallel-mode-enabled DHCP offer is sent using primary IPv4 address to the client for multiple offers received from server for different IPv4 addresses. |
xos0061247 | Configuring IPv6 Syslog target in a specific format produces an incomplete command error, even though the command is complete. |
xos0061331 | Bootprelay for VRF is not supported. Commands to configure bootprelay should reflect this. |
xos0061445 | After creating and enabling an STPD, the command configure "Default" add ports 1 tagged stpd "s1" adds ports to the Default VLAN, but not with STPD domain, even though the error "Command Aborted and no changes were made" appears. |
xos0061465 | IPv6 source address that is not configured on any VLAN in the given VR is accepted as from source IP. Issue does not occur with IPv4. |
xos0061507 | SNMPget on EXTREME-SOFTWARE-MONITOR table returns value with incorrect OID. |
xos0061517 | LACP adjacency fails while forwarding the PDU with l2pt profile over L2VPN tunnels when MPLS PHP is enabled. |
xos0061565 | The TCL function, “clock scan," generates errors with default time zone configuration. |
xos0061656 | Nodes remain in the "FDBSync" state due to temp-flooding while rebooting the stack. |
xos0061788 | The process devmgr ends unexpectedly during snmpwalk when continuous EMS logs are sent to the switch console. |
xos0062017 | DHCP trusted port configuration is lost after disabling, and then re-enabling LAG. |
xos0062018 | For IPv6 routes with mask lengths greater than 64-bits, IPv6 unicast packets destined for the switch CPU can be dropped if another IPv6 route is present with a matching prefix and mask length less than or equal to 64-bits. This issue affects Summit X460-G2, X670-G2, and X770 switches. |
xos0062133 | STP flush event does not happen after ports are quickly disabled, and then enabled. |
xos0062145 | With QoS configuration, ACL process signal 11 ends unexpectedly after rebooting. |
xos0062240 | Port that was administratively disabled becomes up after enabling rx pause. |
xos0062271 | CLI memory leak occurs when executing show commands with include option through script. |
xos0062277 | The command show vlan vlan_list does not show information for dynamic VLANs nor the Default VLAN. Error appears. |
xos0062290 | Due to ExtremeXOS reflection RSTP BPDU support, upstream bridges believe that they are receiving their own BPDUs (contain the bridge's ID), thus causing multisource events during topology changes, which can cause slow convergence times when lp is configured (upwards of 30 seconds). |
xos0062427 | EDP process ends unexpectedly when CDP packets without portId TLV are received. |
xos0062441 | The process rtMgr ends unexpectedly when IPv6 static route is deleted. |
xos0062472 | Source MAC addresses learned through CDP packets received on EAPS-blocked ports cause traffic to be dropped. |
xos0062570 | In SummitStacks, executing the command enable sflow ports all enables sFlow inappropriately on stacking ports. |
xos0062705 | Kernel oops can occur after clearing IPMC FDB in a stack. |
xos0062789 | Disabling learning on LAG ports does not flush FDB entries. |
xos0062879 | Transceiver information shows same Rx power value for 4x10G partition ports even though some ports are in ready state. |
xos0063089 | Kernel oops triggered infrequently during continuous addition/deletion of ARP entries for long durations. |
xos0063359 | The process rtmgr might end unexpectedly after executing disable bgp, and then enable bgp, or after disable port, and then enable port, or after rebooting a switch containing BGP routes. |
xos0063368 | In an MLAG configured switch, FDBs are not installed in hardware after reboot if there are frequent MACMoves between MLAG port and ISC. |
xos0063134 | Traffic stops after disabling, and then enabling LAG porst having pstag with static FDB |
xos0063245 | With IGMP per-VLAN mode, VRRP flaps occur after adding tagged ports to VLANs. |
xos0063457 | Configuration for adding network VLAN port in STP for subscriber is not saved. |
xos0063521 | A few IBGP routes are not updated in routing table when disable bgp and enable bgp commands are executed in quick succession. |
Summit X460-G2 Series Switches | |
xos0061486 | Combo ports have unsupported autonegotiation and half-duplex settings. |
xos0062425 | On Summit X460-G2 series switches, the primary port is incorrectly set as 40 when it should be 41. Under certain conditions, this can cause a kernel crash. |
xos0062855 | On the Summit X460-G2 series switches, VPLS packets are forwarded with two tags when the service VLAN ports are also members of an untagged VMAN. |
xos0063071 | Add support for ONEPolicy IP socket classification. |
Summit X450-G2 Series Switches | |
xos0060129 | On Summit X450-G2 series switches, 10/100/1000BASE-T SFP+ optics do not link to similar optics when in the SFP/SFP+ ports. They do link or partially link when connected to a regular triple speed copper port. |
xos0061704 | With SSH2 enabled, reboot the switch and force some other standby node to become the master node. Key becomes invalid on new master node. |
Summit X670-G2 | |
xos0061791 | On SummitStacks containing master and standby nodes of different switches, the standby node may go to failed state after a node reboot. |
xos0062166 | On Summit X670-G2 series switches configured with L3VPN, executing the clear iparp command causes the switch to reboot with Kernel Oops. |
xos0063204 | Traffic stops on LAG ports when frequently modifying the sharing group. |
SummitStack | |
xos0057835 | In SummitStacks, clear-flow sampling period is incorrectly calculated. |
xos0061799 | Precedence order between policy port rules and policy MAC-based rules is not preserved following a master/backup Failover. |
xos0061841 | FDB entries are not learned again after limit learning is unconfigured, and then configured again, with PSTAG configuration in SummitStacks. |
xos0061957 | HAL process ends unexpectedly during failover when switches have ACL policy without meter action. |
xos0062084 | Rebooting modules with only policy configurations clears their policy port configurations when they rejoins the stack. |
xos0062123 | Port groups do not appear in the show configuration command. However, they do appear in the show ports group command. |
xos0062238 | On a stacked system, configuration of a user-defined CoS value's etsysCos8021dPriority using the MIB can return success when the set actually failed (as seen by a subsequent get). |
xos0062291 | Applying the same policy MAC admin rule to multiple ports produces the following error message: hardware configuration of rule failed for policy. |
xos0062367 | ACL process ends unexpectedly on repeated refresh of ACL policy with clear-flow action. |
xos0062504 | You can set a GPTP "peer delay current interval" outside of the correct range of -3 to 17.. |
xos0062522 | In SummitStack switches, standby slots go to failed state when a very large number of log messages are continuously generated in the switch. |
xos0063242 | Stacks configured as DHCP clients do not respond to pinging after failover. |
xos0063344 | With MLAG and LAG configurations, when a stack node comes up after a reboot, FDB entries flooded from other slots are programmed on incorrect ports internally. |
xos0063490 | CFM stays down after slot reboot on a stack. |
ACL | |
xos0054348 | Cannot delete flow names after deleting, and then creating, the flow while the ACL is installed. |
xos0054714 | When ACLs are applied in both ingress and egress directions, you cannot see egress direction using SNMP. When a policy has more than one counter, using SNMP, you can only check the updates from the first counter, and subsequent counters do not appear. |
xos0059924 | The output of the command show access-list meter ports displays additional meter name when only one meter is applied using ACL policy. |
xos0060716 | Need support for new ACL action "redirect-vlan" to redirect matched packets to all ports in specified VLANs. |
xos0061922 | Dynamic ACLs applied as "any" fail to install in hardware after upgrading ExtremeXOS from any release other than EXOS 15.3. |
xos0062156 | ACL Manager API slice type can be off by one. |
xos0062537 | HAL crash occurs when redirect-port-list action contains more than 64 ports. |
xos0062619 | SSH access-profile using policy does not work with IPv6 addresses. |
xos0063172 | ACL action "redirect-port-list" does not take effect when another slice has a rule to match all packets with deny action. |
xos0063240 | ACL process ends unexpectedly when switch has clear-flow ACL rule with count interval greater than snmptrap generation timer. |
xos0063547 | Process ACL ends unexpectedly after applying a policy file with source zone as a match condition. |
AVB | |
xos0062494 | Source MAC addresses learned through MVRP packets on a blocked port (STP) cause traffic to be dropped. |
BGP | |
xos0058441 | After creating a BGP peering session between link local IPv6 addresses with the scope ID specified, deleting the VLAN containing link local IPv6 address. and then issuing the command show configuration bgp, switch reboots with Epm application wdg timer warning error message. |
xos0060641 | When BGP is administratively shut down, it does not send notifications to peers. |
xos0060680 | Switch stops responding after executing clear bgp neighbor all counters on a switch without BGP configuration. |
xos0060749 | Configuring, enabling, disabling, or deleting BGP neighbors using link local
address results in the following error message:
Error: cmBackendXmlParseEnd Failed to convert "bgpCfgPeerRemoteAddr" value "fe80::204:96ff:fe97:efef/brian-to-112" |
xos0061129 | In a multi-peer setup with many routes (over 150K), a few routes from the preferred peer do not become active in the BGP RIB. Disabling, and then re-enabling peer, restores all routes. |
xos0061411 | Route table installs sub-optimal BGP routes (next-hop) to kernel, while the BGP RIB shows different paths when same routes are received from two different peers in local-RI |
xos0061505 | After a topology change in the network, BGP routes requiring two levels of recursive lookup are programmed in hardware with incorrect next hops. |
xos0062260 | BGP process ends unexpectedly when local address or password is changed for BGP neighbor, and then you immediately execute a BGP show/configuration command. |
xos0055051 | When applying an import policy to BGP, cost configured in the policy is not applied to route tables. This issue is not resolved after multiple policy refreshes nor after multiple disabling, and then enabling BGP. |
xos0063173 | Process dcbgp ends unexpectedly with signal 11 after issuing the command show bgp neighbor. |
Chalet | |
xos0060354 | ExtremeXOS Chalet using IPv6 does not work with HTTPS. |
xos0062016 | Command line process memory leak occurs when accessing switches with Chalet. |
xos0063255 | In Chalet, VLANs are sorted incorrectly. |
ClearFlow | |
xos0062629 | Clearflow rule does not work properly if there is dot(.) in the ACL counter. |
EAPS | |
xos0061038 | Loops occur in EAPS-protected VLANs, after peer reboot, if a VLAN‘s port is also protected by ELSM. |
xos0061385 | EAPS process ends unexpectedly after deleting EAPS shared-port configuration. |
ELRP | |
xos0062460 | The show configuration command output shows incorrect ELRP configuration. |
xos0062618 | ELRP forgets the disabled port information if the port is deleted from another VLAN that also has ELRP enabled. As a result, the disabled port stays disabled unless manually enabled. |
ESRP | |
xos0061965 | Configuring ESRP member VLANs (VRRP-enabled) produces errors. |
FDB | |
xos0059481 | Static FDB is programmed incorrectly in hardware after a stack failover. |
IGMP | |
xos0062914 | The process mcmgr ends unexpectedly after receiving corrupted IGMPv3 join packets on MLAG ports. |
LAG\MLAG | |
xos0062428 | Member ports with a modified speed configuration that is different than the master port should not be allowed in LAG. |
xos0063365 | Frequent MLAG bulk syncs observed due to checksum mismatch between MLAG peers when ISC port was added as an untagged port to a tagged VLAN and VRRP was running between the peers. |
MPLS | |
xos0059596 | Can add more than one LSP a pseudo-wire when it is associated with a VPWS. |
xos0061092 | Traffic forwarding on VPLS-serviced VMAN stops after link flap. |
xos0061943 | MPLS process ends unexpectedly when get-next is done with incomplete OID for mplsXCIndex. |
xos0062045 | LLDP packets are tunnelled over L2VPn. |
xos0062300 | CEP CVID Ranges, other than first VLAN, fail when access port is a trunk. |
xos0062301 | Packet drops occurs between customer edge switches when VMAN and CVID tag are the same. |
xos0062380 | Switch rejects incorrect LSP configurations as expected, but this operation still uses LSP indexes in hardware. |
xos0062754 | VPLS traffic egresses out with dot1q tag when secondary EtherType is configured. |
xos0063271 | Layer 3 packets in non-default virtual routers are slow-path forwarded after disabling MPLS in the peer switch. |
xos0063478 | Traffic drop occurs while adding new member port to the existing LAG group and PSTAG is configured on the port. |
OpenFlow | |
xos0060531 | Deleting VMAN deletes the VLAN configuration, but not associated OpenFlow logical ports. |
Optics | |
xos0059007 | QSFP+ to SFP+ adapter support is added to work with all optical SFP+ transceivers with the exception of LRM and passive copper direct attach cables. |
xos0060018 | With a 0.5M, 40G QSFP MOLEX passive copper cable inserted, disabling the port where the optic is inserted, rebooting, and then enabling the port, the port stays in the ready state and doesn't come up as enabled. |
xos0060264 | The output of the show port transceiver info command for optics inserted in 40G/100G ports might be abnormally lengthy if the same command is executed from two different CLI sessions simultaneously. |
xos0062719 | Allow use of 3rd-party optics without any additional license. |
xos0063120 | Error message "CFP2 modules >= 18 W unsupported" incorrectly appears for Finisar Corp CFP2 LR4 optics. |
OPSFV2 | |
xos0061855 | Configured OSPF neighbor is not retained after rebooting. |
xos0063380 | Error message appears after rebooting switch with OSPF configuration: "Error while loading "ospfInterface": ERROR: 0.0.0.0 is not a valid configured neighbor for interface". |
Power | |
xos0062113 | The show power command output does not display power usage for PSUs with part numbers starting with “800515”. |
QoS | |
xos0061027 | For SummitStacks, creating or deleting non-default QoS profiles may cause some ports to flap. |
xos0062050 | QoS committed rate configurations for port groups are not loaded properly after a save and reboot. |
Security | |
xos0057679 | Account user name and password are not encrypted in logs when cli-config-logging is enabled. |
xos0058808 | Rarely, MAC addresses of authenticated clients learned on NetLogin-enabled ports are not programmed in hardware. |
xos0060909 | In UPM profiles the variable EVENT.TIME incorrectly has the current time rather than the time when the event was queued/triggered. |
xos0061433 | extremeNetloginUserLogoutTrap is received with errors. |
xos0061597 | After authenticating a NetLogin client, executing the command clear netlogin state port, and then checking that ID-mgmt has deleted the clients, log displays UnDscvrId EMS message, which does not indicate the identity user. |
xos0061652 | Netlogin Dot1x: Authenticated value should be "Yes, Local" for clients with invalid password authenticated on auth failure VLAN. |
xos0061781 | Identity manager entries become stale when clients are moved from one port to another in sub-VLANs. |
xos0061797 | Dot1x client moves to authentication failure VLAN if authentication failed due to incorrect supplicant password or framework failure, such as error in VLAN movement, etc.; even if web-based NetLogin is enabled. |
xos0061820 | Dot1x clients move to authentication failure VLAN when web-based NetLogin is enabled globally. |
xos0061868 | With protocol order as MAC dot1x, web-based UPM profile is not executed for the client, which is authenticated as MAC. |
xos0062366 | After rebooting, DHCP binding entries are not restored using vr-default. |
xos0062674 | UPM profile fails to set the variables received from the RADIUS server using VSA 212. |
xos0062965 | Policy process ends unexpectedly with signal 6 when master node goes down. |
xos0063090 | NetLogin client does not move into authfail VLAN when user is absent from local database. |
xos0063248 | NTP MD5 authentication with NTP server is failing. |
xos0063445 | NetLogin: FDB is not in synch when changing VLAN VSA's dynamically. |
xos0063506 | Traceroute MAC address in CFM domain does not return information about destination switch. |
SNMP | |
xos0059964 | SNMP poll for MIB dot3StatsDuplexStatus always returns unknown(1) when ports are configured with auto-negotiation on. |
xos0060792 | SNMP authentication failure log message and trap is inappropriately generated when switch detects "Not In Time Windows" error. |
xos0061379 | Switch temperature value retrieved using SNMP get operation is incorrect. |
xos0061886 | SNMP master process ends unexpectedly with signal 6 with certain sequence of snmpbulkget and snmpget. |
xos0061945 | SnmpSubagent crash occurs when snmpset executed on the last row in EAPSMbrVlanEntry. |
xos0063349 | Switch stops responding to SNMP requests if SNMP get for multiple OIDs is continuously initiated. |
STP | |
xos0062701 | HAL timeout occurs while rebooting a stack with STP configuration. |
TWAMP | |
xos0062217 | In SummitStacks with eight nodes and sFlow configuration, "Hardware L3 Table full" error messages appear when the stacks have a large number of Layer 3 entries. |
VLANs | |
xos0054039 | IP multicast traffic is not forwarded on PSTAG VLANs when it shares ports with other IGMP snooping-enabled VLANs or other L3 VLANs. |
xos0060184 | After configuring MVRP registration forbidden, the command is accepted and registration is forbidden. However, the show configuration mrp command does not display this configuration and this configuration is not saved after a reboot. |
xos0062255 | CEP CVID configurations is missing after adding/deleting the port from sharing. |
xos0063207 | Error occurs while adding LAG ports as tagged in one VMAN and untagged in another VMAN, even though the VMAN EtherType is primary. |
xos0063257 | Saving configuration fails/times-out when VLANs added to a mirror filters are renamed. |
xos0063274 | VLAN packets are egressing with VMAN ethertype when an egress port is deleted from a VMAN that is also part of a VLAN. |