The following issues were resolved in ExtremeXOS 21.1.3-Patch1-4. ExtremeXOS 21.1.3-Patch1-4 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, ExtremeXOS 21.1.2, and ExtremeXOS 21.1.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0052786 | BGP aggregation command demands global unicast addresses (GUA) and does not work with IPv6 unicast addresses. |
xos0054222 | Unable to add second IPv6 address prefix to the network-zone after adding IPv4 address. |
xos0064727 | On DHCPv6 clients, sometimes the IPv6 address is not removed even after
disabling the client, and after rebooting, the IPv6 address is saved and this causes
the client to go into a stopped state with the following error message appearing:
<Erro:vlan.AddIPAddrFail> Failed to add IP addr 8001::4aa6:dd38:9b32:e7b/128 from DHCPv6 to VLAN client, DHCPv6 configured IPv6 address already exist on interface client |
xos0065654 | Etmon process ends unexpectedly with signal 10 when packet size in sampled packet is a negative integer. |
xos0066072 | The command configure ports rate-limit flood out-actions disable-port does not take effect until the command clear meter out-of-profile is executed. |
xos0066444 | Kernel error "Unable to copy IPMC index" appears in MLAG peers with PIM dense mode. |
xos0066590 | In an MLAG peer when its MLAG port is down, the following error appears: "Group <ip> not found for VLAN". |
xos0066770 | Memory leak occurs in aaa process when NetLogin dot1x client times out or authentication fails for the client. |
xos0066775 | Configured peer group capabilities and policies are not reflected after creating a new BGP neighbor. |
xos0066874 | Memory leak observed in AAA process when dot1x clients are authenticated frequently. |
xos0066923 | Need commands to configure "reload-delay" timer for MLAG ports. |
xos0066931 | Exsshd process consumes ~90% CPU when the command clear session is executed for the open SSH sessions. |
xos0066982 | In NetLogin dot1x, RADIUS retries are not working properly. |
xos0067055 | Log message "Process exsshd sends hello too often" appears when SSH is enabled in the switch. |
xos0067076 | NetLogin process ends unexpectedly while fetching the client details using SNMP MIB etsysMACAuthenticationMACSession and it happens only when there is MAC move observed for the clients. |
xos0067194 | Topology change notification is not generated for the STP domain dot1d mode when there is change in the topology. |
xos0067203 | Multicast packets are being flooded on EAPS blocked port while removing and adding the ports configured with PSTAG. |
xos0064672 | Incorrect state observed for DHCPv6 client when restarting the nettools process or rebooting the switch. |
xos0066489 | Loop occurs in ERPSv2 setup after rebooting one of the interconnecting nodes. |
xos0066490 | ERPS in non-RPL nodes remains in pending state after rebooting interconnection node. |
xos0062966 | When rendezvous point receives (*, G) join, and it has (S, G, RPT) entry, the
entry should be converted to (S, G), and (S, G) join should be sent upstream.
However, sometimes wrong assert is triggered and this new entry is dropped after a
minute, resulting in complete traffic loss. Workaround: Disable, and then re-enable
PIM.
|
xos0066012 | ExtremeXOS MIBs have non-compilable errors. |
xos0066030 | L2PT is not working properly after path switchover in VPWS. |
xos0066386 | The show configuration commands stops responding and produces an error when there is a loop in the network. |
xos0066518 | LLDP packets are reflected back to the sender without echo kill in PVLAN. |
xos0066813 | Service VLAN ARP packets are lifted to the CPU during MPLS swap operation when service a VLAN is configured with the IP address of the provider switch. |
xos0066891 | Packets are being forwarded without a tag after rebooting when PSTAG configured. This issue occurs when VLANs are configured with VID as "1". |
xos0066926 | Errors occur when configuring OpenFlow in passive mode. |
xos0066950 |
Hash collision error messages may appear when there is contention for the L3 Hash table: <Warn:Kern.IPv4Adj.Warning> vrId 0 adj 0x00000002 Error finding adjacency when deleting hash collision. |
xos0066986 | OSPF E1 routes in NSSA area are removed/not updated properly in the routing table |
xos0067048 | Multicast traffic is not forwarded on PStag ports when port is also added as part of another non-PStag VLAN. |
xos0067138 | BFD is not working for IP static multicast route. |
xos0066774 | IPv6 flow redirect does not work after slot is disabled, and then enabled again. |
xos0066040 | Error message appears when adding a CEP port to a VMAN:
<Erro:HAL.MPLS.Error> pibAddCVIDMappedServices: vlan 1000 tagged 0 cepPvid 100 |
xos0066667 | With VPLS, multicast traffic for service VLAN is dropped after disabling and enabling the LAG ports if same port is configured as untagged in VMAN and tagged in VLAN. |
xos0063856 | On enabling SSH2, switch displays key generation time as approximately 15 minutes whereas it actually takes less than one minute. |
xos0067328 | If you load a configuration file containing an SSH key length lesser than the actual key size stored in the switch EEPROM, the following message appears during bootup: "Enter passphrase:". |
xos0063261 | Warning message to "restart process exsshd" should appear when configuring SSH2 key. |
xos0066406 | Scaled PStag configuration with non-PStag VLANs causes PStag error messages and installation of additional IPMC rules. |
NWI Series Switches | |
xos0066301 | Transceiver is not detected on NWI platforms. |
SummitStack | |
xos0067096 | Multicast traffic is dropped on front panel port 1:1 when management port goes down on stacking switch. |
xos0067253 | IPv4 packets ingressing a non-master stack node can be dropped when the port number of the destination's ARP entry is unknown, such as when the destination is using Network Load Balancing (NLB). |
xos0066423 | In SummitStacks, with policy re-authentication and continuous MAC move scenarios, ACL delete requests are failing in backup node. |
Summit X460-G2 Series Switches | |
xos0057796 | Power is momentarily denied to PoE devices connected on ports when a redundant PSU is inserted. |
xos0067077 | In Summit X460-G2 alternate stacks, 10G links from the VIM-2T module of the backup slot go down after saving, and then rebooting. |
Summit X770 Series Switches | |
xos0053091 | In Summit X770 series switches, additional link flaps occur on 40G ports after reboot. |