Resolved Issues in ExtremeXOS 21.1.1-Patch1-5

The following issues were resolved in ExtremeXOS 21.1.1-Patch1-5. ExtremeXOS 21.1.1-Patch1-5 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3 and ExtremeXOS 21.1.1. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 21.1.1-Patch1-5

CR Number Description
General
xos0055541 TACACS: On configuring shared secret key in encrypted form with characters "&" and "<" , the show configuration aaa output shows a different secret key from what was actually configured.
xos0057931 After rebooting the switch multiple times, following error log message appears:
<Erro:cm.loadErr> Failed to load configuration: timed out (after 150 seconds) while waiting for all applications to get ready to load configuration on OPERATIONAL ( eaps is still not ready yet)
.
xos0062265 Some legacy commands are not recognized.
xos0062444 Kernel panic occurs in DoS protect-enabled switches when TCN SYN packets to port 80 are flooded to Management port.
xos0063331 VLAN IP address is unconfigured when modifying the VLAN name/port information from Chalet.
xos0063332 Configuration changes to VPLS are not fully retrieved by SNMP walk, which returns values for only few VPLS index.
xos0063842 Packets are being flooded in both network and access VLAN ports after port flap.
xos0063995 SNMP sysUpTime does not return correct value after failover.
xos0064009 MLAG+EAPS:Traffic forwarding stops after EAPS that include ISC link converges.
xos0064054 SNMPwalk on extremeAclStatsTable returns value with port instance instead of ifIndex.
xos0064055 Resiliency Enhancement for IPv4 and IPv6 Static Routes feature has been added.
xos0064063 Packet-Resolution match conditions need to be added as ACL match conditions.
xos0064075 The output of the show fan command shows fan status as "Failed" after hot re-seating a fan module.
xos0064129 Policy refresh never completes with network-zone configuration.
xos0064151 Error occurs when removing DHCP configuration from VLANs when LAG ports are added to the VLANs.
xos0064178 Hardware entries not released on disabling of ports in a LAG connecting an L2VPN router to the MPLS core when L2VPN sharing is configured and in use.
xos0064179 MAC movement occurs in switch acting as an STP root bridge when PVST+ BPDUs are sent by peer switch using STP blocked port.
xos0064203 Incorrect next hop is chosen by BGP route after port flap.
xos0064215 The following log message appears when a subnet is reachable both using MPLS and non-MPLS:
<Warn:Kern.IPv4FIB.Warning> Slot-4: dest 0x0A420000 / 24 nexthop 0xAC11121E: Unable to add route to unit 1, rc Entry not found. Shadow problem.
xos0064223 Need to add an ACL match condition for matching next-hop addresses during the look-up cycle of a packet, so that actions can be taken based on the next-hop a packet is destined for.
xos0064278 In a SummitStack or BlackDiamond chassis, FDB is not programmed in hardware after three failovers and fallback.
xos0064281 In Chalet, switch inappropriately displays logs for user accounts under enhanced security mode.
xos0064299 The hal process ends unexpectedly after executing the command debug packet capture on.
xos0064307 RADIUS accounting configuration is incorrect as shown by the command show conf aaa and is lost after upgrade.
xos0064319 Aggregated BGP route is not transmitted to upstream neighbor when highest prefix route is received from neighbor.
xos0064326 LACP flaps when the LAG port is added to VMAN, with the VMAN ethertype same as LACP ethertype.
xos0064357 Out of sync between PIM and RTMgr process after introducing new best route.
xos0064383 In the show l2vpn detail command output, the "PW Tx Pkts" counters are not updated for VPWS sessions even though traffic is passing correctly.
xos0064395 STP digest value gets changed when adding the port in VLAN or removing the port from VLAN.
xos0064490 After upgrading from ExtremeXOS 15.2 to later release, last installed dynamic ACL rule is given more priority than previously installed rules.
xos0064519 With MVR enabled on two VLANs, IGMP report packets are looped if sent to all hosts group.
xos0064589 While learning BGP routes, some routes are not getting installed in route table when deleting and re-adding the static route.
xos0064033 In Summit X670 series switches, traffic gets software forwarded after disabling/enabling members of a shared group and recreating the shared group after deletion.
xos0062720 Unable to save configuration when ACL/CFM is configured on multiple VLANs.
xos0063429 The output of the command show fan shows the fan status as empty after a hot re-seating of the fan module.
xos0064400 When switch boots up with factory default configuration, Zero Touch Provisioning (ZTP+) is enabled automatically and IP is resolved correctly using DHCP, but this causes flooding to be disabled on all ports.
xos0063693 With L2VPN sharing, traffic loss occurs after LSP failover.
xos0061018 After failover, traffic fails across VPLS configured with 64 LSPs across LAG.
xos0064312 With VXLAN, if tenant VLAN and tunnel are on different VRs, FDB is not learned on a tunnel.
xos0063844 With VXLAN, MLAG port in backup slot is not added to aggregator after reboot of switch followed by disable and enable of port.
xos0064136 Unable to configure flood rate limit as 1 packets per second.
Summit X670 Series Switches
xos0057671 Link status goes to Ready state on port with 10/100/1000BASE-T optics after multiple reboots.
xos0063263 On Summit X670 series switches, 1000BaseSX optics are incorrectly detected as 100BaseFX.
SummitStack
xos0061834 In SummitStacks, the command synchronize stacking slot <slot no> does not work from master node if the target slot is in failed state.
xos0061861 A per-port meter configured on a SummitStack may not be properly configured on the backup node following a reboot.
xos0062484 EPM process crashes on master if image upgrade on a standby slot exceeds 30 minutes.
Summit X670-G2 Series Switches
xos0064574 In X670G2, IPMC cache entries are limited to 5000, when the lookup key is changed from Source-Group-Vlan to Group-Vlan mode or vice versa.
BlackDiamond X8 Series Switches
xos0064010 The command show port buffer displays an incorrect port range for 100G I/O modules.
xos0060666 After failover, traffic gets flooded on the ports of service VLAN in H-VPLS core.
Summit X440 Series Switches
xos0063627 ARP is not re-added to hardware after it is removed initially due to the table being full.