The following issues were resolved in ExtremeXOS 22.7.2-Patch1-7. ExtremeXOS 22.7.2-Patch1-7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 22.7, and ExtremeXOS 22.7.2. For information about those fixes, see the release notes for the specific release.
Defect Number | Description |
---|---|
General | |
EXOS-26408 | The command disable stpd s0 appears twice in the configuration if STP is disabled, and if the default STPD mode of s0 domain is changed. |
EXOS-27179 | HAL process ends unexpectedly on master node of SummitStack if stacking-related show command is run during unconfiguration of some other stacking slot. |
EXOS-27133 | ExtremeXOS adds a prefix of csr- to the common name in the Certificate Sign Request (CSR). |
EXOS-26916 | DNS packets are not processed on NetLogin VLAN when the IP address is re-configured, and when a NetLogin web-enabled port is not a member of the NetLogin VLAN. |
EXOS-24068 | Need a provision to cancel out the correct field in pdelayresponse/pdelayresfollowup messages while calculating neighbor rate ratio. |
EXOS-27225 | During VPLS fallback scenarios, convergence happens within a second and causes communication loss between CE devices. |
EXOS-27194, EXOS-27034 | VPLS FDB is leaked on network VLAN when a flap occurs on MPLS cloud. |
EXOS-27079 | The process exsshd ends unexpectedly when adding/deleting the user name with 'space'. |
EXOS-27047 | The process "mcmgr" ends unexpectedly after receiving IGMP report packet if MVR is enabled globally on user virtual router (VR), but not on the VRF. |
EXOS-26464 | During TFTP get operations, if the local file name is mentioned as just a period ("." ), then the permissions for home directory is changed. |
EXOS-27091 | HAL process ends unexpectedly when ExtremeXOS retries to detect unsupported or third-party optics. |
SummitStack | |
EXOS-26393 | The command show inline-power slot master_slot fails after a node is added/replaced with the automatic stacking. |
EXOS-26299 | HAL process ends unexpectedly when hosts move from network VLAN to subscriber VLAN. |