The following issues were resolved in ExtremeXOS 22.7.1-Patch1-15. ExtremeXOS 22.7.1-Patch1-15 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, and ExtremeXOS 22.7. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 22.7.1-Patch1-15
CR Number Description
General
xos0075914 DHCP: DNS domain names from a server are not updated to the DNS proxy.
xos0076092 ExtremeXOS VM: DNS server information obtained from DHCP is not installed properly.
xos0076153 Fabric Attach (FA) uplink port is removed from FA Mgmt VLAN after ZTP+ configuration is pushed.
xos0076376 ELRP packets are transmitted with checksum errors.
xos0076430 Process hal ends unexpectedly with signal 11 after unconfiguring a standby slot when policy is enabled.
xos0076447 TLS transactions sometime encounter issues when clients send packets after a delay.
xos0076593 OSPF AS external routes are removed when one of the two paths go down out of which one is inter area path and another is intra area path.
xos0076686 For ExtremeXOS 16.2 and later, SSH has a 3–5 seconds delay for prompt password window to appear.
xos0076705 Cable diagnostics are not working on Summit X460G2-16mp switches.
xos0076764 After failover, OSPFv3 routes are not removed from new master node.
xos0076186 ONEPolicy rules are not taking effect if CoS is configured in the profile.
xos0076956 IPFIX does not work on a stack when a master node does not support IPFIX.
xos0076816 The NTP association takes a while to be updated when the interface goes down or comes back up.
xos0077005 In an STP with MLAG configuration, ISC port cost should appear as "0" under the command show stp domain_name ports output.
Extended Edge Switching
xos0076250 One-armed Extended Edge Switching MLAG cannot be formed using MLAG ID 1 and 2.
xos0076298 With cross-connected MLAG configuration, a few CSP sessions are not opened after multiple failovers of controlling bridge (CB).
xos0075645 Extended Edge Switching ring goes to severed state after rebooting controlling bridge (CB) with rebalancing on.
xos0076323 Extended Edge Switching ring stays in "Formation disabled" state after rebooting a tier 1 slot, or disabling, and then enabling, native cascade ports.
xos0076318 Extended Edge Switching ring remains in severed state after rebooting all slots with traffic.
xos0076295 The output of the command show vpex port is not showing MLAG ID information when more than a single one-arm MLAG ring is configured.
xos0076299 Extended Edge Switching ring: Multicast traffic loss occurs when adding a new member port to a native cascade LAG.
xos0076387 Extended Edge Switching ring: OSPF goes down when adding a new member port to a native cascade LAG.
xos0076149 Error log "pibAddPortToDot1BrVlanBitMap" occurs when Extended Edge Switching MLAG ring is coming up after a reboot.
xos0076154 On ring common (RC) link, LAG member ports are not added as aggregator.
xos0076161 One-armed MLAG: Extended Edge Switching remains in the "Formation Disabled" state after disabling, and then enabling, of the native cascade port.
xos0076227 In Extended Edge Switching ring topology after rebooting a bridge port extender (BPE) in the severed state, Multicast traffic is dropped.
xos0076242 After a ring common link flap, the Extended Edge Switching ring sometimes does not recover and stays in the "Severed" state.
xos0076245 Extended Edge Switching ring: IPMC "Unable to Del L2" error logs occur when deleting ports from VPLAG.
xos0076343 Traffic loss occurs after enabling LAGs on extended VLAN ports.
xos0076348 In an MLAG and Extended Edge Switching ring topology, when trying to form a ring from a cascade chain, traffic is dropped.
xos0076371 After a controlling bridge (CB) failover, LACP sessions go down resulting in traffic loss.
xos0076557 Ring common link LAG member does not converged properly in cross-connect MLAG ring.
xos0076607 One-armed MLAG: Flood traffic is blackholed after an intermediate slot is removed.
xos0076460 Rebalancing is not happening after a slot is removed from a cross-connect MLAG Extended Edge Switching ring.
xos0076628 After a controlling bridge (CB) reboot, Multicast traffic loss occurs for slots connected by a one-armed ring.
xos0073946 On Extended Edge Switching controlling bridge (CB) switches, the show inline-power stats command takes longer than usual to display the output, and sometimes it returns "Timeout occurred while retrieving information from hardware." messages.
xos0076462 Cross-connect MLAG: LAG members are not added after adding a new slot with rebalancing turned on.
xos0076398 The time taken for the an eight-node Extended Edge Switching ring(with two PoE slots) to go to the complete state is excessive (approximately 6 mins).
xos0076689 One-armed MLAG: Disabling, and then enabling, ports on a controlling (CB) breaks the MLAG-Extended Edge Switching ring and it remains in a severed state.
xos0076541 Flood traffic is dropped at bridge port extender (BPE) if A VLAN is added to the extended port after breaking the ring.
xos0076765 The hal process ends unexpectedly when a one-armed MLAG ring is formed with an MLAG ID greater than 64,000.
xos0075272 "UV/OV" fault is not cleared after the PoE limit is exceeded, and then returned back within the acceptable range.
xos0076965 After an ISC flap in one-armed ring topology, FDB is not learned on a slot.