Resolved Issues in ExtremeXOS 22.7.2-Patch1-3

The following issues were resolved in ExtremeXOS 22.7.2-Patch1-3. ExtremeXOS 22.7.2-Patch1-3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 22.7, and ExtremeXOS 22.7.2. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 22.7.2-Patch1-3
Defect ID Description
General
EXOS-24110 Combining MLAG and VLAN-translation can cause reachability issues.
EXOS-24220 SNMP walk fails when trap receiver is configured using SNMP community strings starting with "v,w,x,y,z".
EXOS-24136 Convergence takes 6 seconds when port down/up coincides with optics polling interval (once in 300 secs).
EXOS-24138 Hardware-assist BFD sessions go down after changing the egress VLAN tag.
EXOS-19921 In policy mode with NSI mapping configured and a client authenticated on a port, if the port is manually added to authentication (destination) VLAN and another client is authenticated on the same port, then continuous flush occurs.
EXOS-26203 BGP route is showing the incorrect gateway after network events, such as link flap, underlying LSP flap, or OSPF route convergence.
EXOS-24285 Configuring ELRP on a very large number of ports results in rejection of the command with the message “Configuration reply is too big”.
EXOS-24134 FDB entries learned on NetLogin-enabled bridge port extender (BPE) ports point to CPU, causing traffic loss.
EXOS-24129 Add the ability to disable and enable DDMI (Digital Diagnostic Monitor Interface) polling using the CLI.
EXOS-23879 VLAN process ends unexpectedly while doing SNMP polling on EXTREME-VLAN-PORT MIB.
ExtremeSwitching X460-G2
EXOS-24116 BFD sessions on the Default VLAN go down after enabling hardware-assistance.
SummitStack
EXOS-24127 Synchronize stacking command fails to synchronize the stack.
EXOS-24060 On SummitStacks, when port is in software learning mode, FDB is not programmed in hardware on all slots resulting in flooding.
EXOS-26220 On SummitStacks with PoE-capable switches, the PoE process ends unexpectedly after running the show tech command.
EXOS-20360 Occasionally, FDB is not learned after stack failovers on ExtremeSwitching X465, X590, X690, X695, and X870 series switches.
ExtremeSwitching X690
EXOS-24098 With a loopback port disabled, BFD sessions remain in the init state when a switch is rebooted.