Resolved Issues in ExtremeXOS 22.7.1-Patch1-24

The following issues were resolved in ExtremeXOS 22.7.1-Patch1-24. ExtremeXOS 22.7.1-Patch1-24 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, and ExtremeXOS 22.7. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 22.7.1-Patch1-24
CR Number Description
General
xos0068638 If NetLogin authentication mode option is selected, the web authentication commands should fail and show the error message "ERROR: web-based and "authentication optional" cannot be enabled simultaneously on a port".
xos0076140 IPv6 ping is fails over PSTag.
xos0076261 With NetLogin authentication mode optional configured, the first packet used for for authentication is not forwarded/flooded to other ports in the VLAN.
xos0076294 Memory leak occurs in thttpd process while accessing network web login page, causing a switch reboot.
xos0076372 NetLogin users session is not cleared on a port even after the port is moved to blocking state by STP.
xos0076373 Unable to create multiple authentication failure VLANs.
xos0076851 On MLAG topologies after an ARP refresh, unicast ARP response is flooded.
xos0074324 After running the switch for long time with policy and mirroring enabled, memory leak occurs in hal process.
xos0075519 A policy admin-profile macsource rule might be removed by a mac move condition or by clearing users with the mib etsysMultiAuthStationClearUsers.
xos0074772 Policy process ends unexpectedly after configuring authentication mode as optional through SNMP MIB or Extreme Management Center when NetLogin web-based authentication is enabled.
xos0074107 Kernel oops occurs with continuous addition and deletion of policy rule.
xos0074713 Authentication type appears as "Yes, Radius" for Dot1x users even though the users have been moved to the Service-Unavailable VLAN due to no RADIUS availability.
xos0077218 When NetLogin is enabled, LLDP Neighbors are not discovered on LAG ports.
xos0076850 After a stack failover, FDB and ARP entries are not removed on MLAG peers.
xos0076413 After disabling sharing, the following error message appears: <Crit:VSM.ParmInv> Slot-2: Argument Ingress Port Instance has an invalid.
xos0073815 NetLogin Dot1x authentication fails when limit learning is configured on port-based VLANs.
ExtremeSwitching X870 Series Switches
xos0077740 On ExtremeSwitching X870 series switches, hardware VLAN tables are not updated correctly when enabling OpenFlow.
xos0077775 On ExtremeSwitching X870 series switches, Extreme-certified optics are detected as "unknown".
ExtremeSwitching X690 Series Switches
xos0076930 On ExtremeSwitching X690 series switches, even though "Auto-negotiation OFF" is configured on a port, the port defaults to "Auto-negotiation ON" at the hardware level after a reboot.
SummitStack
xos0076321 ELRP takes 3–15 seconds to disable a loop detected on a port on a standby node.
xos0072797 When upgrading a stack to ExtremeXOS 22.7, FDB filter checkpoint failed error occurs.
xos0076395 In policy, mac-based feature is not working after unconfiguring, and then reconfiguring a slot where the client is connected.
xos0075517 Running the command show policy convergence-endpoint connections ports all produces a Python error message on the backup slot.
xos0074778 Policy process ends unexpectedly with continuous traffic with a scaled number of users.
Extended Edge Switching
xos0076561 VPLAG member port traffic is dropped when there is client traffic on the LAG master port.
xos0075921 In Extended Edge Switching, NetLogin mac users are not checkpointed to non-authenticator on multi-authication ports after runnning the command clear netlogin state agent mac on authenticator.
xos0076360 Dot1x client is not authenticated on tagged port on Extended Edge Switching ring.
xos0075344 FDB entries are not removed from hardware table after disabling, and then enabling, policy causing MAC addition to fail on subsequent user authentication.
xos0076492 In Extended Edge Switching with MLAG ring topology, FDB is not learned for one-armed MLAG slot after master failover or reboot.
xos0075808 With orchestration mode enabled, the command "restart process vsm" does not restart the process.