The following issues were resolved in ExtremeXOS 22.7.3. ExtremeXOS 22.7.3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 22.7, and ExtremeXOS 22.7.2. For information about those fixes, see the release notes for the specific release.
Defect Number | Description |
---|---|
General | |
EXOS-27448 | IPv6 DAD state remains in Tentative state after two failover attempts if an interface is disabled after the first failover. |
EXOS-27563 | Need a CLI command to disable OCSP for TLS connections to remote Syslog servers. |
EXOS-26424 | Need support for 802.1w mode in ezspantree script. |
EXOS-27489 | When downloading the image, SCP sync fails on backup node. |
EXOS-27713 | After configuring RADIUS management access, Telneting to other slots using auto-login does not work as expected. |
EXOS-27216 | Update show fdb command output to show age as 0 for hardware aging platforms. |
EXOS-27505 | The rtmgr process ends unexpectedly while performing recursive route table lookup. |
EXOS-27718 | After running port statistics-related commands, the CLI stops responding. |
EXOS-27827 | After upgrading toExtremeXOS 22.7 and later, a few processes, such as thttpd, remain in load configuration state if there is a large amount of VLAN configuration. |
EXOS-26489 | A JSON request for a configuration change or save (admin privilege) fails for RADIUS-authenticated users. |
EXOS-27198 | Even though booted and running configurations are identical, the command show configuration difference output displays differences. |
EXOS-27715 | ELRP process ends unexpectedly after receiving an invalid packet with ELRP destination MAC address. |
EXOS-27399 | STP operational edge status is not set to "TRUE" for ports linked up in non-default speeds, such as 100M or 10M. |
SummitStack | |
EXOS-10809 | Non-partitioned 40G ports in backup/standby slots are showing incorrect port status after stack reboots. |
EXOS-27755 | In SummitStacks, need support for active monitoring of fan status/failures. |
EXOS-27385 | In SummitStacks, STP memory leak occurs on backup node for each MLAG port flap on a peer switch. |