The following issues were resolved in ExtremeXOS 22.7.2-Patch1-5. ExtremeXOS 22.7.2-Patch1-5 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 22.7, and ExtremeXOS 22.7.2. For information about those fixes, see the release notes for the specific release.
Defect Number | Description |
---|---|
General | |
EXOS-26289 | The command show port transceiver info detail is not displaying output for all ports. |
EXOS-24139 | Traffic loss occurs when default route is installed with IProute compression enabled. |
EXOS-26241 | LLDP process crash occurs when IPv6 address encodes a TLV. |
EXOS-26500 | Root switch becomes isolated when root bridge goes down in STP. |
EXOS-10862 | Switch receives IGMPv1 queries from ExtremeXOS IGMP querier configured as IGMPv2. |
EXOS-26602 | Traffic between hosts using LAG are not getting hashed using the same port with XOR hash algorithm if the number of sharing ports are not power of 2. |
EXOS-24286 | ELRP disabled logs are not cleared even after enabling the disabled port. |
EXOS-26452 | Extended Edge Switching: Bridge port extender (BPE) LACP lag port is not joining in aggregate after a controlling bridge (CB) reboot. |
EXOS-26301 | Redundant message appear in show port port# transceiver info detail output when DDMI (Digital Diagnostic Monitoring Interface) is disabled on the port. |
ExtremeSwitching X460-G2 Series Switches | |
EXOS-26262 | Excessive MAC move notifications appear from hardware if a bulk number of FDB entries age out at same time. |
SummitStack | |
EXOS-26416 | On SummitStack, HAL process spike occurs in master node when standby node power is lost. |
ExtremeSwitching X870 Series Switches | |
EXOS-26316 , EXOS-26406 | Finisar modules detected unsupported or UNKNWN after a switch reboot. |
EXOS-26396 | On ExtremeSwitching X870 series switches, some 40G ports remain in Ready state after restarting the ports or rebooting the switch. |