configure inline-power usage-threshold
    
    
        
      
                configure inline-power usage-threshold threshold
            
    
        Description
      
      Sets the inline power usage SNMP event
                threshold.
    
        Syntax Description
      
      
                        
                            | threshold | Specifies the percentage of
                                budgeted power used on any PoE switch
                                that causes the system to send an SNMP event and create a log
                                message. The range 1 to 99; the default value is 70. | 
                    
    
        
        Usage Guidelines
      
      This command sets the threshold for generating an SNMP event and an EMS
                message. On a SummitStack, this threshold is when the measured power for a PoE
                module compared to the budgeted power for that slot exceeds a certain value. On
                stand-alone switches, this threshold applies to the total power available to the
                entire switch. The configured threshold value initiates the event and message once
                that percentage of the budgeted power is being used.
      The
system generates an additional SNMP event and EMS message once the
power usage falls below the threshold again; once the condition
clears.
    
        Example
      
      The following command
sets the inline power usage alarm threshold at 75%:
      configure inline-power usage-threshold 75
    History
      
      This command was first available in ExtremeXOS 11.1.
    
        Platform Availability
            
            This command is available on: 
            
            
                    - ExtremeSwitching
                            5420F-8W-16P-4XE—ExtremeXOS 31.3 and
                        later.
- ExtremeSwitching
                            5420F-24P-4XE—ExtremeXOS 31.3 and
                        later.
- ExtremeSwitching
                            5420F-16MW-32P-4XE—ExtremeXOS 31.3 and
                        later.
- ExtremeSwitching
                            5420F-16W-32P-4XE—ExtremeXOS 31.3 and
                        later.
- ExtremeSwitching
                            5420F-48P-4XE—ExtremeXOS 31.3 and
                        later.
- ExtremeSwitching
                            5420F-48P-4XL—ExtremeXOS 31.3 and
                        later.
- ExtremeSwitching
                            5420M-16MW-32P-4YE—ExtremeXOS 31.3 and
                        later.
- ExtremeSwitching
                            5320-48P-8XE—ExtremeXOS 31.6 and
                        later.
- ExtremeSwitching
                            5320-24P-8XE—ExtremeXOS 31.6 and
                        later.
- ExtremeSwitching
                            5320-16P-4XE—ExtremeXOS 31.7 and
                        later.
- ExtremeSwitching
                            5320-16P-4XE-DC—ExtremeXOS 31.7 and
                        later.
                - ExtremeSwitching 5520-24W—ExtremeXOS 31.1 and later.
- ExtremeSwitching 5520-48W—ExtremeXOS 31.1 and later.
- ExtremeSwitching 5520-12MW-36W—ExtremeXOS 31.1 and later.
- ExtremeSwitching 5420F-8W-16P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420F-16MW-32P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420F-16W-32P-4XE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-24W-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-16MW-32P-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5420M-48W-4YE—ExtremeXOS 31.3 and later.
- ExtremeSwitching 5720-24MW—Switch Engine 32.1 and later.
- ExtremeSwitching 5720-24MXW—Switch Engine 32.1 and later.
- ExtremeSwitching 5720-48MW—Switch Engine 32.1 and later.
- ExtremeSwitching 5720-48MXW—Switch Engine 32.1 and later.