Displays the MEP CCM database.
| domain_name | Enter the name of the domain for which you want to display the MEP CCM databases. | 
| association_name | IEEE 802.1ag or ITU-T Y.1731 association name. | 
| port_list | Enter the ports in the domain/association for which you want to display the CCM databases. | 
| up | Enter this to display the CCM database on the UP MEP for the specified MA. | 
| down | Enter this to display the CCM database on the DOWN MEP for the specified MA. | 
N/A.
If you do not specify any parameters or variables, the system displays information on all CCM databases on the switch.
The name of the domain and association
Port number
MP and type
MAC address of remote end points
MEP IDs
Lifetime for CCM messages from each remote end point

Note
The TTL for the CCM messages from the MP you are working on is 3.5 times the transmission interval.
The following command displays the CCM databases on the switch:
show cfm detail
The following is sample output from this command:
# show cfm detail 
Domain/       Port     MP   Remote End-Point   Remote End-Point MEP    Life        Flags 
 Association                  MAC Address        IP Address      ID     time  Age
===================================================================================
dnsname 
10             1        UE   00:04:96:51:5f:15 0.0.0.0           300    3500  650    DMA
dom1 
VSNLMEG1       1        DE     -------------    0.0.0.0           300    11    0     SMA               
               1        DE     -------------    0.0.0.0           400    11    0     SMI 
               15       DE     -------------    0.0.0.0           300    35    0     SMA
               15       DE     -------------    0.0.0.0           400    35    0     SMI
dom1  
 short_ma_name 1        DE     -------------    0.0.0.0           300    11    0     SMA
               1        DE     -------------    0.0.0.0           400    11    0     SMI
               15       DE     -------------    0.0.0.0           300    3500  0     SMA
               15       DE     -------------    0.0.0.0           400    3500  0     SMI
dom2 
VSNLMEG1       1        UE    00:04:96:51:5f:15 0.0.0.0           300    3500 750   SUA
00:11:22:33:4 
VSNLMEG1       1        UE    00:04:96:51:5f:15 0.0.0.0           300    3500 760   DMA
00:11:22:33:4 
 short_ma_name 1        UE   00:04:96:51:5f:15  10.10.10.2        300    3500 90    DMA
===================================================================================
Maintenance Point: (UE) Up End-Point, (DE) Down End-Point
Flags: (S) Static Entry, (D) Dynamic Entry       
       CCM Destination MAC: (U) Unicast, (M) Multicast       
       Status: (A) Active, (I) Inactive
NOTE: The Domain and Association names are truncated to 13 characters, Lifetime      
      and Age are in milliseconds.
=================================================================================== 
Total Number of Dynamic Up RMEP      : 3
Total Number of Dynamic Down RMEP    : 0
Total Number of Active Static RMEP   : 5
Total Number of Inactive Static RMEP : 4
        This command was first available in ExtremeXOS 11.4.
This command is available on all ExtremeSwitching Universal switches.