The AP3000X comes with the AH-ACC-BKT-AX-TB mounting bracket that can be used to mount the access point on flat surfaces, such as Prelude ceilings (15/16 in. ceiling grid), Suprafine ceilings (flat bottomed 9/16 in. ceiling grid), and walls. The ceiling tile sides must be flat.
Note
An integral antenna is an antenna that's fixed to the AP and cannot be disconnected. An integral antenna is also called a fixed antenna or integrated antenna and can be an internal or external antenna.Note
Unlike with earlier APs, you do not need to order two AI-DS0305360-RPSMA antennas seperately. They are included with the AP.Antenna | Technical Specifications | ||||
---|---|---|---|---|---|
2.4GHz | 5.0GHz | ||||
Port | Gain | Beam | Gain | Beam | |
ML-2452-HPAG4A6-01 | 1 | 4 | 360 | 7.3 | 360 |
ML-2452-PNA5-01R | 1 | 4.5 | 120 | 5 | 120 |
ML-2452-APA2-01 | 1 | 3.04 | 360 | 4.96 | 360 |
ML-2452-APA2-02 | 1 | 3.04 | 360 | 4.96 | 360 |
ML-2452-HPA5-036 | 1 | 3.9 | 360 | 5.7 | 360 |
ML-2452-PTA2M2-036 | 2 | 4 | 360 | 5 | 360 |
ML-2452-SEC6M4-036 | 4 | 6.92 | 100 | 7.3 | 80 |
AI-DS0305360-RPSMA | 1 | 3.23 | 360 | 5.22 | 360 |
AIO-DD75060-RPSMA | 2 | 7.5 | 60 | 7.5 | 60 |
AIO-DD05120-RPSMA | 2 | 5 | 120 | 5 | 120 |
Purchase one of the following accessories if you are installing the access point on a surface other than a standard flat surface.
Accessory | Description |
---|---|
AH-ACC-BKT-AX-TB |
Mounting bracket that can be used to mount the access point on flat surfaces such as Prelude ceilings (15/16 in. ceiling grid), Suprafine ceilings (flat bottomed 9/16 in. ceiling grid), and walls. Note: AH-ACC-BKT-AX-TB is included with the access point.
|
AH-ACC-BKT-AX-IL |
Mounting bracket for Interlude ceilings (9/16 in. wide T-bar with center protrusion). |
AH-ACC-BKT-AX-SL |
Mounting bracket for Silhouette ceilings (ceiling grid with 1/8 in. or 1/4 in. bottom opening). |
AH-ACC-BKT-AX-WL |
Mounting bracket for direct-to-wall installations when a 1.25 inches of space is desired between the wall and the access point. |
ACC-BKT-TB-NF | Mounting bracket for 15/16 in. wide T-bars with sculpted ceiling tiles. |
AH-ACC-BKT-916-KIT | Mounting bracket for 9/16 in. wide T-bars with sculpted ceiling tiles. |
ACC-BKT-AX-TBW | Mounting bracket for 1.5 in. wide T-bars. |
ACC-BKT-AX-BEAM |
Mounting bracket for beam mounting. |
ACC-BKT-AX-JB |
Mounting bracket for junction box or wall mounting. |
You can power the access point through the ETH0 RJ45 Ethernet port. But if you need to power the AP with an external power supply, you can purchase a 12V DC power supply.
There is no wall mount bracket for the 12VDC power supply.
Part number | Description |
---|---|
37215 |
PWR 12 VDC, 2A (24W), 2.5 mm X 5.5 mm connector |
The following table shows the additional accessories available for your access point.
Part number | Description |
---|---|
ACC-WIFI-MICRO-USB |
Extreme Networks micro USB cable. Note: When you
connect to the device using the micro USB Console port, the
management station from which you connect to the device must
have a VT100 emulation program, such as TeraTerm Pro (a free
terminal emulator) or Hilgraeve HyperTerminal. Set your baud
rate to 115200.
|