Mount the Access Point to a Wall Using the
Phillips Pan-Head Screws
About this task
You
can mount the access point directly onto a drywall or a solid wall using the Phillips
pan-head screws. This is an optional installation method and not the preferred mode of
installation.
Procedure
Drill two holes 104 mm (4.100
in.) apart from each other on the wall where you want to mount the
AP.
Insert the screws into the holes and use the screw-in anchors if needed.
Note
Leave 1/8th gap between the
screw head and the wall.
Insert the Ethernet cable‘s RJ45 connector into the LAN1 port.
Align the AP against the screw
heads and slide it down.
Ensure that the AP is secured in place and tightened. If the AP is loose,
unmount the AP and decrease the distance between the screw head and the wall.
Remount the AP.