Shows information about the bridge port extender (BPE) attached to the specified cascade ports.
|
If you do not specify any ports, information for all cascade ports appears.
In a redundant CB configuration, the M flag in the output of this command indicates the CB occupying the master role.
The following example shows information for BPEs attached to all cascade ports:
# show vpex ports
Port Cascade Ext Port Link PECSP PE CSPOpen CSP Role
# Port Slot State State MAC Address MAC Address Loc Rem Flags
===========================================================================================
1:72 1:72 100 E A d8:84:66:88:98:3a d8:84:66:88:98:07 1 1
33:52 33:52 101 E A d8:84:66:88:98:3b d8:84:66:88:98:22 1 1 MC
===========================================================================================
Port State: D-Disabled, E-Enabled, F-Disabled by link-flap detection,
L-Disabled due to licensing
Link State: A-Active, R-Ready, NP-Port Not Present, L-Loopback,
CSP Role Flags: B-Backup, C-State Complete, I-State Init, M-Master,
T-State Transitioning, U-Unknown.
This command was first available in ExtremeXOS 22.5.
This command is available on the Summit X670-G2 and ExtremeSwitching X690 series switches.