device# cfm loopback domain md1 ma ma1 src-mep 101 target-mep 200
Following are the parameters which you can configure for the CFM loopback domain command.
The domain name parameter specifies the maintenance domain to be used for a loopback message. The name attribute is case-sensitive.
The ma ma-name parameter specifies the maintenance association to be used for a loopback message. The ma-name attribute is case-sensitive.
The src-mep mep-id parameter specifies the Source ID in the range 1-8191.
The target- mip HHHH:HHHH:HHHH parameter specifies the MAC address of the MIP loopback destination.
The target-mep mep-id parameter specifies the Destination ID in the range 1-8191.
The number number parameter specifies the number of loopback messages to be sent.
The timeout timeout parameter specifies the timeout used to wait for loopback reply.