overlay-gateway/{gateway-name}/site/{site-name}/bfd
 
   
   
	  Usage
 
		 
		<overlay-gateway xmlns="urn:brocade.com:mgmt:brocade-tunnels">
	<name>og1</name>
	<site>
		<name>site1</name>
		<bfd>
			<params>
				<interval>
					<min-tx>110</min-tx>
					<min-rx>330</min-rx>
					<multiplier>3</multiplier>
				</interval>
			</params>
		</bfd>
	</site>
</overlay-gateway>
 
	 
 
	  Parameters
 
		 
		 
		   
			 - name 
			 
  
			 - Specifies the site name 
			 
  
		   
		   
			 - min-tx 
			 
  
			 - Specifies BFD desired minimum transmit interval in milliseconds. The value can range from 100 through 30000. The default value is 100.
			 
  
		   
		   
			 - min-rx 
			 
  
			 - Specifies BFD desired minimum receive interval in milliseconds. The value can range from 300 through 30000. The default value is 300. 
			 
  
		   
		   
			 - multiplier 
			 
  