Positioning the AP for Installation

Mount the AP so that the vent side is always down. Insert and crimp a ground wire to the provided terminal. You must provide a 3-inch drip loop on all cables. Use the M4 ground screw assembly, with the star washer, to attach the ground wire‘s ring terminal to the back of the AP. The wire should be as close to the AP bottom as possible. Tighten the screw to a torque of 13.0-13.5 in-lbs.

Note

Note

Attach the ground wire to the AP before attaching any bracket.
Note

Note

Do not remove the dust cap until you need to install the BLE/ IoT antennas.