This section describes the procedure to mount the AP3917i/e to a wall or a pole using the 10" WS-MBO-ART01 2-Axis extension arm (part number
30514).
-
Attach the large bracket to the AP using four M4 screw assemblies. Torque them
to 12 in-lbs.
-
Insert the two large locking screws into the metal bracket holes marked zero.
On the threaded end add one flat washer, one split washer, and one hex nut. Turn
the nut only a couple of turns on the threads.
-
If you are mounting the other end to a pole, insert the two desired cable
clamps and then attach the small bracket end to the pole bracket using four M4
screws. Torque the screws to 12 in-lbs.
Important
The wall must be strong enough to
support the AP during inclement weather.
-
Attach the cable clamps to the pole where desired.
Torque the clamp screws to 15 in-lbs.
-
If mounting the other end to a wall, attach the small bracket end to the wall
with four screws. Torque the screws to 15 in-lbs.
-
If the AP needs to be tilted up or down, remove
the locking screw and tilt the AP to the desired angle. Re-insert the locking
screw into the center hole in the black part of WS-MBO-ART01. Torque the locking
screw and nut to 12 in-lbs.
-
If the AP needs to be turned sideways, remove the
locking screw and tilt the AP to the desired angle. Re-insert the locking screw
into the center hole in the black part of WS-MBO-ART01. Torque the locking screw
and nut to 12 in-lbs.
-
Remove the black gland cap and the gasket under
it. Then separate the gasket from its plastic cage.
-
Attach the gland parts to the LAN cables and
insert the LAN cables into the mating connectors in the AP.