Backup and Restore Alerts

Use the information in the following tables to learn about all possible backup and restore alerts that are raised by Fault Management.

System Backup Initiated

31070 System Backup Initiated
Description Send an alert when a backup is initiated.
Preconditions None
Requirements

Alert shows the following data:

  • User
  • Version
  • Backup Type
  • Fabric Name
  • Fabric All
  • Device IPs
The following example shows an alert when a system backup is initiated:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - -     
   [meta sequenceId=”47”]   
   [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”]   
   [alert@1916   
   resource=””  
   alertId=”31070”  	   
   cause=”operationInitiated”
   type=”communicationsAlarm”
   severity=”info”]
   [alertData@1916   
   user=”extreme”
   version=”3.3.0-backup”
   backup_type=”FabricName”
   fabric_name=”nonclos”
   fabric_all=””
   device_ips=””]  
   BOMSystem backup type "FabricName" initiated for fabric "nonclos" for efa version "3.3.0-backup" by user "extreme".
Health Response Health resources are not associated with system backup.

System Backup Success

31071 System Backup Success
Description Send an alert when backup is successful.
Preconditions You initiated a system backup or a periodic backup.
Requirements

Alert shows the following data:

  • User
  • Version
  • Backup Type
  • Fabric Name
  • Fabric All
  • Filename
The following example shows an alert when a system backup is successful::
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - -     
   [meta sequenceId=”47”]   
   [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”]   
   [alert@1916   
   resource=””  
   alertId=”31071”  	   
   cause=”operationSuccess”
   type=”communicationsAlarm”
   severity=”info”]
   [alertData@1916   
   user=”extreme”
   version=”3.3.0-backup”
   backup_type=”FabricAll”
   fabric_name=””
   fabric_all=true
   device_ips=””
   filename="/apps/efa_logs/backup/XCO-3.3.0-backup-2022-12-07T19-05-31.719.tar”]  
   BOMSystem backup type "FabricAll" completed successfully for efa version "3.3.0-backup" by user "extreme" located at "/apps/efa_logs/backup/XCO-3.3.0-backup-2022-12-07T19-05-31.719.tar".
Health Response Health resources are not associated with system backup.

System Backup Failure

31072 System Backup Failure
Description Send an alert when the backup operation fails.
Preconditions You initiated a system backup or a periodic backup.
Requirements

Alert shows the following data:

  • User
  • Version
  • Backup Type
  • Fabric Name
  • Fabric All
  • Device IPs
  • Error
The following example shows an alert when backup fails for a device:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - -     
   [meta sequenceId=”47”]   
   [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”]   
   [alert@1916   
   resource=””  
   alertId=”31072”  	   
   cause=”operationFailure”
   type=”processingErrorAlarm”
   severity=”major”]
   [alertData@1916   
   user=”extreme”
   version=”3.3.0-backup”
   backup_type=”DeviceIP”
   fabric_name=””
   fabric_all=””
   device_ips=”10.24.80.55,10.24.80.57”
   error=” Config backup Failed for device: [10.24.80.55,10.24.80.57], Reason: Devices do not exist”]  
   BOMSystem backup type "DeviceIP" failed for device ips "10.24.80.55,10.24.80.57" for efa version "3.3.0-backup" by user "extreme" due to " Config backup Failed for device: [10.24.80.55,20.24.80.57], Reason: Devices do not exist ".
Health Response Health resources are not associated with system backup.

System Backup Restore Initiated

31075 System Backup Restore Initiated
Description Send an alert when the backup restore operation is initiated.
Preconditions None
Requirements

Alert shows the following data:

  • User
  • Version
  • Filename
The following example shows an alert when a system restore is initiated from a backup:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - -     
   [meta sequenceId=”47”]   
   [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”]   
   [alert@1916   
   resource=””  
   alertId=”31075”  	   
   cause=”operationInitiated”
   type=”communicationsAlarm”
   severity=”info”]
   [alertData@1916   
   user=”extreme”
   version=”3.3.0-backup”
   filename=” XCO-3.3.0-backup-2022-12-05T15-48-54.920.tar”]  
   BOMSystem restore initiated with "XCO-3.3.0-backup-2022-12-05T15-48-54.920.tar" on XCO version "3.3.0-backup" by user "extreme".
Health Response Health resources are not associated with system restore.

System Backup Restore Success

31076 System Backup Restore Success
Description Send an alert when the restore operation is successful
Preconditions You initiated a system restore.
Requirements

Alert shows the following data:

  • User: User who initiated this restore operation
  • Version: version
  • Filename: Backup file that was restored
The following example shows an alert when a system restore is successful:
Syslog RFC-5424 Example: 
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - -     
   [meta sequenceId=”47”]   
   [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”]   
   [alert@1916   
   resource=””  
   alertId=”31076”  	   
   cause=”operationSuccess”
   type=”communicationsAlarm”
   severity=”info”]
   [alertData@1916   
   user=”extreme”
   version=”3.3.0-backup”
   filename=” XCO-3.3.0-backup-2022-12-05T15-48-54.920.tar”]  
   BOMSystem restore completed successfully with "XCO-3.3.0-backup-2022-12-05T15-48-54.920.tar" on XCO version "3.3.0-backup" by user "extreme"
Health Response Health resources are not associated with system restore.

System Backup Restore Failure

31077 System Backup Restore Failure
Description Send an alert when a system restore fails.
Preconditions You initiated a system restore.
Requirements

Alert shows the following data:

  • User
  • Version
  • Filename
  • Error
The following example shows an alert when the system retire fails from a backup:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - -     
   [meta sequenceId=”47”]   
   [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”]   
   [alert@1916   
   resource=””  
   alertId=”31077”  	   
   cause=”operationFailure”
   type=”processingErrorAlarm”
   severity=”major”]
   [alertData@1916   
   user=extreme””
   version=”3.3.0-backup”
   filename=” XCO-3.3.0-backup-2022-12-05T15-48-54.920.tar”
   error=”reason for failure”]  
   BOMSystem restore failed with "XCO-3.3.0-backup-2022-12-05T15-48-54.920.tar" on XCO version "3.3.0-backup" by user "extreme"
Health Response Health resources are not associated with system restore.

System Backup Restore Out of Order Sequence ID

31078 System Backup Restore Out of Order Sequence ID
Description Send an alert when the sequence number is out of order due to system backup and restore.

The alert indicates that the existing sequence number is out of order, and a new sequence number from the backup tar file takes effect.

Preconditions Backup tar file already has the alerts.
Requirements

Alert shows the following data:

  • None
The following example shows an alert when the sequence number goes out of order for backup and restore:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - -     
   [meta sequenceId=”47”]
   [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”]   
   [alert@1916   
   resource=””
   alertId=”31078”  	   
   cause=”informationOutOfSequence”
   type=”integrityViolation”
   severity=”info”] 
   BOMAlert sequence number can go out of order.
Health Response Health resources are not associated with out of order system sequence.