Use the information in the following tables to learn about all possible fabric health alerts in detail that are raised by Fault Management.
31600 | Port Flap Alert |
---|---|
Description | Send an alert when there is continuous port flap on a registered fabric device port. |
Preconditions | The SFP is faulty or there are other hardware issues. The number of admin up is greater than configured threshold within a specified time interval. |
Requirements |
Alert shows the following data:
The following is an example of a port flap alert:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”” alertId=”31600” cause=”excessiveErrorRate” type=”communicationsAlarm” severity=”warning”] [alertData@1916 device_ip=”10.x.x.x” port=”Ethernet 0/1”] BOM The Port flap detected for device 10.x.x.x, port ethernet 0/1 |
Health Response |
Response
{ Resource: /App/Component/Asset/Device?device_ip=10.x.x.x&port=Ethernet0/1 HQI { Color: Red Value: 0 } Status Text: Port Ethernet0/1 on device 10.x.x.x is flapping continuously. } |
31706 | Managed Fabric Physical Topology Degraded Notice |
---|---|
Description | Send an alert when the fabric level physical topology health is changed from to Green to Red. |
Preconditions | Fabric is created and devices are added in XCO. The severity for physical topology errors is Major. The fabric services generate the alerts when the following conditions are not met:
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric level physical
topology health is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Topology/Physical?fabric_name=fb” alertId=”31706” cause=”missingSpines” type=”fabricService” severity=”major”] [alertData@1916 fabric_name=”fb” fabric_health_info=”{ Missing_spines: true} }” ] BOM The fabric “fb” is missing spines. |
Health Response |
Response
{ Resource: /App/Component/Fabric/Topology/Physical?fabric_name =fb HQI { Color: Red Value: 3 } StatusText: The fabric “fb” is missing spines } |
31707 | Managed Fabric Physical Topology Healthy Notice |
---|---|
Description | Send an alert when the fabric level physical topology health is changed from Red to Green. |
Preconditions | Fabric is created and devices are added in XCO. The fabric services generate the alerts when the following conditions are met:
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric level physical
topology is in healthy
condition:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Topology/Physical?fabric_name=fb” alertId=”31707” cause=”fabricPhysicalTopologyHealthRestored” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” fabric_health_info=”” ” ] BOM The fabric “fb” has fabric physical topology in healthy state |
Health Response |
Response
{ Resource: /App/Component/Fabric/Topology/Physical?fabric_name =fb HQI { Color: Green Value: 0 } StatusText: The fabric “fb” has fabric physical topology in healthy state. } |
31708 | Managed Fabric Device Appstate Degraded Notice | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Description | Send an alert when fabric device app state health is changed from Green to Red or Black. | ||||||||||||||||||
Preconditions |
Fabric is created and devices are added in XCO. Application state changes based on adding devices, configuring success or failure, drift in configurations. The alert has the following app states and the corresponding
severity:
|
||||||||||||||||||
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device app
state health is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Configuration/AppState?fabric_name=fb&device_ip=10.x.x.x” alertId=”31708” cause=”configReady” type=”fabricService” severity=”major”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”{AppState: cfg ready}” ] BOM The device “10.x.x.x” of fabric “fb” has app state set to cfg ready. |
||||||||||||||||||
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Configuration/AppState?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Red Value: 3 } StatusText: The device “10.x.x.x” of fabric “fb” has app state set to cfg ready } |
31709 | Managed Fabric Device Appstate Healthy Notice | ||||||
---|---|---|---|---|---|---|---|
Description | Send an alert when fabric device app state health is changed from Red or Black to Green. | ||||||
Preconditions |
Fabric is created, and devices are added and configured in XCO so
that the App state changes to The alert has the following app states and the corresponding
severity:
|
||||||
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device app
state is
healthy:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Configuration/AppState?fabric_name=fb&device_ip=10.x.x.x” alertId=”31709” cause=”appStateHealthRestored” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”” ] BOM The device “10.x.x.x” of fabric “fb” has app state set to healthy. |
||||||
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Configuration/AppState?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Green Value: 0 } StatusText: The device “10.x.x.x” of fabric “fb” has app state set to healthy } |
31710 | Managed Fabric Device Provisioning State Degraded Notice | ||||||
---|---|---|---|---|---|---|---|
Description | Send an alert when fabric device provisioning state health is changed from Green to Black or Red. | ||||||
Preconditions |
Fabric is created, and devices are added in XCO. The alert has the following app states and the corresponding
severity:
|
||||||
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device
provisioning state health is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Configuration/DevState?fabric_name=fb&device_ip=10.x.x.x” alertId=”31710” cause=”notProvisioned” type=”fabricService” severity=”major”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”{ DevState: not provisioned}” ] BOM The device “10.x.x.x” of fabric “fb” has dev state set to not provisioned. |
||||||
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Configuration/DevState?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Red Value: 3 } StatusText: The device “10.x.x.x” of fabric “fb” has dev state set to not provisioned. } |
31711 | Managed Fabric Device Provisioning State Healthy Notice |
---|---|
Description | Send an alert when fabric device provisioning state health is changed from Black or Red to Green. |
Preconditions |
Fabric is created, and devices are added and configured in XCO so that the devices move to provisioned state (Severity - Info). |
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device
provisioning state is
healthy:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Configuration/DevState?fabric_name=fb&device_ip=10.x.x.x” alertId=”31711” cause=”devStateHealthRestored” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”” ] BOM The device “10.x.x.x” of fabric “fb” has dev state set to healthy. |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Configuration/DevState?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Green Value: 0 } StatusText: The device “10.x.x.x” of fabric “fb” has dev state set to healthy. } |
31712 | Managed Fabric Device MCT Cluster Degraded Notice | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Description | Send an alert when fabric device MCT cluster health is changed from Green to Red or Black. | ||||||||||||||||||||||||||||||||||||
Preconditions |
Fabric is created and MCT devices are added and configured in XCO. An alert is raised if any of the following cluster operational states are down:
|
||||||||||||||||||||||||||||||||||||
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device MCT
cluster state is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Mct?fabric_name=fb&device_ip=10.x.x.x” alertId=”31712” cause=”mctClusterStateAndPeerKeepAliveStateDown” type=”fabricService” severity=”major”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”{ PeerKeepAliveState: false ClusterState: false }” ] BOM The device “10.x.x.x” of fabric “fb” has MCT cluster state and peer keep alive state down. |
||||||||||||||||||||||||||||||||||||
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Operational/Mct?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Red Value: 3 } StatusText The device “10.x.x.x” of fabric “fb” has MCT cluster state and peer keep alive state down } |
31713 | Managed Fabric Device MCT Cluster Healthy Notice |
---|---|
Description | Send an alert when fabric device MCT cluster health is changed from Red or Black to Green. |
Preconditions |
Fabric is created and MCT devices are added and configured in XCO. An alert is raised if all the cluster operational states are up (Severity: Info):
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device MCT
cluster state is
healthy:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Mct?fabric_name=fb&device_ip=10.x.x.x” alertId=”31713” cause=”deviceMctClusterHealthRestored” type=”fabricService” severity=”info”] [alertData@1916 name=”fb” device_ip=”10.x.x.x” fabric_health_info=”” ] BOM The device “10.x.x.x” of fabric “fb” has MCT cluster in healthy state. |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Operational/Mct?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Green Value: 0 } StatusText The device “10.x.x.x” of fabric “fb” has MCT cluster in healthy state } |
31714 | Managed Fabric Device Physical Topology Degraded Notice |
---|---|
Description | Send an alert when fabric device physical topology health is changed from Green to Red. |
Preconditions |
Fabric is created and devices are added and configured in XCO. Alerts are raised if the physical topology validation fails. The severity for physical topology errors is Major. Alerts are raised if the following conditions are not met:
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device
physical topology health is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Topology/Physical?fabric_name=fb&device_ip=10.x.x.x” alertId=”31714” cause=”missingLinks” type=”fabricService” severity=”major”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”:{ Errors:[ { Destination_ip: 10.x.x.a Destination_Role: leaf Device_links:[ {Error: missing_links} ] }, Destination_ip: 10.x.x.b Destination_Role: leaf Device_links:[ {Error: missing_links} ] ] ” ] BOM The device “10.x.x.x” of fabric “fb” has missing-links with devices [10.x.x.a,10.x.x.b]. |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Operational/Topology/Physical?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Red Value: 3 } StatusText The device “10.x.x.x” of fabric “fb” has missing-links with devices [10.x.x.a,10.x.x.b]. } |
31715 | Managed Fabric Device Physical Healthy Notice |
---|---|
Description | Send an alert when fabric device physical health is changed from Red to Green. |
Preconditions |
Fabric is created and devices are added and configured in XCO. Alerts are raised if the device physical topology validation is successful. The severity for device physical topology errors is Info. Alerts are raised if the following conditions are met:
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device
physical health is Green
(healthy):
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Topology/Physical?fabric_name=fb&device_ip=10.x.x.x” alertId=”31715” cause=”devicePhysicalTopologyHealthRestored” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”” ] BOM The device “10.x.x.x” of fabric “fb” has physical topology in healthy state. |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Operational/Topology/Physical?fabric_name=fb&device_ip=10.x.x.x.a HQI { Color: Green Value: 0 } StatusText The device “10.x.x.x” of fabric “fb” has physical topology in healthy state. } |
31716 | Managed Fabric Device Underlay Degraded Notice |
---|---|
Description | Send an alert when fabric device underlay health is changed from Green to Red or Black. |
Preconditions |
Fabric is created and devices are added and configured in XCO. The alerts are raised if the session state of any of the BGP neighbors is not established.
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device
underlay health is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=“3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Topology/Underlay?fabric_name=fb&device_ip=10.x.x.x” alertId=”31716” cause=”underlayNeighborsNotConfigured” type=“fabricService” severity=”major”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”:{Errors:[ { Destination_ip: 10.x.x.a Destination_Role: leaf NeighborIP:10.x.x.2 SourceAsn: 6512, DeestinationAsn: 6500 Error: neighbor_not_configured },{ Destination_ip: 10.x.x.b Destination_Role: leaf NeighborIP:10.x,x.3 SourceAsn: 6512, DeestinationAsn: 6500 Error: neighbor_not_configured }],” ] BOM The device “10.x.x.x” of fabric “fb” does not have bgp neighbors configured with [10.x.x.a,10.x.x.b]. |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Operational/Topology/Underlay?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Red Value: 3 } StatusText The device “10.x.x.x” of fabric “fb” does not have bgp neighbors configured with [10.x.x.a,10.x.x.b] } |
31717 | Managed Fabric Device Underlay Healthy Notice |
---|---|
Description | Send an alert when fabric device underlay health is changed from Red or Black to Green. |
Preconditions |
Fabric is created and devices are added and configured in XCO. The alerts are raised if the BGP neighbors session state are in established state. The severity is Info. |
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device
underlay health is Green
(healthy):
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=“3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Topology/Underlay?fabric_name=fb&device_ip=10.x.x.x” alertId=”31717” cause=” deviceUnderlayTopologyHealthRestored” type=“fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”” ] BOM The device 10.x.x.x of fabric fb has underlay topology healthy. |
Health Response |
Response
Resource: /App/Component/Fabric/Device/Operational/Topology/Underlay?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Green Value: 0 } StatusText The device “10.x.x.x” of fabric “fb” has underlay topology in healthy state } |
31718 | Managed Fabric Device Overlay Degraded Notice |
---|---|
Description | Send an alert when fabric device overlay health is changed from Green to Black. |
Preconditions |
Fabric is created, devices are added and configured, and tenant L2 services are configured with common ctag range in XCO. The alerts (Severity: Critical) are raised if the operational or admin status is down. |
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device overlay
health is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=“3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Topology/Overlay?fabric_name=fb&device_ip=10.x.x.x” alertId=”31718” cause=”ovelayTunnelOperDown” type=“fabricService” severity=”critical”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”:{ Errors:[{ Destination_ip: 10.x.x.a Destination_Role: leaf NeighborIP:10.10.10.2 SourceVTEPIP:10.10.10.3, DestinationVTEPIP:10.10.10.6 Admin_state:up, Oper_state: down Error: tunnel_oper_down },{ Destination_ip: 10.x.x.b Destination_Role: leaf SourceVTEPIP:10.x.x.3, DestinationVTEPIP:10.x.x.5 Admin_state:up, Oper_state: down Error: tunnel_oper_down }]” ] BOM The device “10.x.x.x” of fabric “fb” does not have tunnels operationally up with [10.x.x.a,10.x.x.b] |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Operational/Topology/Overlay?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Black Value: 4 } StatusText The device “10.x.x.x” of fabric “fb” does not have tunnels operationally up with [10.x.x.a,10.x.x.b] } |
31719 | Managed Fabric Device Overlay Healthy Notice |
---|---|
Description | Send an alert when fabric device overlay health is changed from Black to Green. |
Preconditions |
Fabric is created, devices are added and configured, and tenant L2 services are configured with common ctag range in XCO. The alerts (Severity: Info) are raised if the tunnel operational and admin status are up. |
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric device overlay
health is Green
(healthy):
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=“3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device/Operational/Topology/Overlay?fabric_name=fb&device_ip=10.x.x.x” alertId=”31719” cause=” deviceOverlayTopologyHealthRestored” type=“fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” fabric_health_info=”” ] BOM The device “10.x.x.x” of fabric “fb” has overlay topology in healthy state. |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device/Operational/Topology/Overlay?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Green Value: 0 } StatusText The device “10.x.x.x” of fabric “fb” has overlay topology in healthy state. } |
31701 | Managed Fabric Deleted Health Notice |
---|---|
Description | Send an alert when fabric is deleted. |
Preconditions | Deletion of an existing fabric. |
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric is
deleted:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com AppFaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric?fabric_name=fb” alertId=”31701” cause=”configRemoved” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” ] BOM : The fabric “fb” is deleted. |
Health Response |
Response
{ Resource: /App/Component/Fabric?fabric_name=fb HQI { Color: Green Value: 0 } StatusText : The fabric “fb” is deleted. } |
31702 | Managed Fabric Device Added Health Notice |
---|---|
Description | Send an alert when a fabric device is added. |
Preconditions | Fabric is created and devices are added. |
Requirements |
Alert shows the following data:
The following example shows an alert when a device is added to
the
fabric:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device?fabric_name=fb&device_ip=10.x.x.x” alertId=”31702” cause=”configCreated” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” ] BOM The device “10.x.x.x” is added to the fabric “fb” |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Green Value: 0 } StatusText : The device “10.x.x.x” is added to the fabric “fb” } |
31703 | Managed Fabric Device Removed Health Notice |
---|---|
Description | Send an alert when a fabric device is deleted. |
Preconditions | Fabric is created. Devices are added and then deleted. |
Requirements |
Alert shows the following data:
The following example shows an alert when an existing fabric is
deleted:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/Device?fabric_name=fb&device_ip=10.x.x.x” alertId=”31703” cause=”configRemoved” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” device_ip=”10.x.x.x” ] BOM The device “10.x.x.x” is removed from the fabric “fb” |
Health Response |
Response
{ Resource: /App/Component/Fabric/Device?fabric_name=fb&device_ip=10.x.x.x HQI { Color: Green Value: 0 } StatusText : The device “10.x.x.x” is removed from fabric “fb”. } |
31704 | Fabric State Degraded Notice |
---|---|
Description | Send an alert when a fabric state health is changed from Green to Red or Black. |
Preconditions | Fabric is created and devices are added in XCO. The following
are the states and the severities of an alert:
|
Requirements |
Alert shows the following data:
The following example shows an alert when an existing fabric is
deleted:
<114> 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/State?fabric_name=fb” alertId=”31704” cause=”fabricSettingsUpdated” type=”fabricService” severity=”major”] [alertData@1916 fabric_name=”fb” fabric_health_info=”{Fabric_status: setting updated}” ] BOM The fabric “fb” has status set to settings-updated due to change in fabric settings [BGP-MD5]. |
Health Response |
Response
{ Resource: /App/Component/Fabric/State?fabric_name=fb HQI { Color: Red Value: 3 } StatusText: The fabric “fb” has status set to settings-updated due to change in fabric settings [BGP-MD5] } |
31705 | Managed Fabric State Healthy Notice |
---|---|
Description | Send an alert when fabric state health is changed from Red or Black to Green. |
Preconditions | Fabric is created and devices are added in XCO. The alert has the
following state changes:
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric is
created:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric/State?fabric_name=fb” alertId=”31705” cause=”fabricStateHealthRestored” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” fabric_health_info=”” ] BOM The fabric “fb” has status set to healthy. |
Health Response |
Response
{ Resource: /App/Component/Fabric/State?fabric_name=fb HQI { Color:Green Value: 0 } StatusText:The fabric “fb” has status set to healthy } |
31700 | Managed Fabric Created Notice |
---|---|
Description | Send an alert when a fabric is created. |
Preconditions | None |
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric is
created:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=“3.3.0”] [alert@1916 resource=”/App/Component/Fabric?fabric_name=fb” alertId=”31700” cause=”configCreated” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” ] BOM : The fabric “fb” is created. |
Health Response |
Response
{ Resource: /App/Component/Fabric?fabric_name=fb HQI { Color: Green Value: 0 } StatusText : The fabric "fb" is created. } |
31799 | Managed Fabric Health Degraded Notice |
---|---|
Description | Send an alert there is a change in fabric health or its contributors. |
Preconditions | Fabric is created and devices are added and configured in the
fabric. Severity is based on the following fabric health color value:
|
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric health is
degraded:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=“3.3.0”] [alert@1916 resource=”/App/Component/Fabric?fabric_name=fb” alertId=”31799” cause=”fabricHealthCritical” type=“fabricService” severity=”critical”] [alertData@1916 fabric_name=”fb” fabric_health_info=” Name : fb Health: Black Devices:[ { Ip: 10.x.x.1, Device_health: Black Oper_state_health:{ Underlay_health:{ Health: Black Errors:[ Source_ip: 10.x.x.1 Source_asn: 6500 Destination_asn: 6512 Destination_ip: 10.x.x.2 Neighbor_ip: 10.x.x.y Underlay_state: CONN Error: session_not_established ] }, } } ] ” ] BOM : Fabric "fb" health is in critical state because the underlay topology has errors for the device(s) [10.x.x.1,10.x.x.2] |
Health Response |
Response
{ Resource: /App/Component/Fabric?fabric_name=fb HQI { Color: Black Value: 4 } StatusText : Fabric "fb" health is in critical state because the underlay topology has errors for the device(s) [10.x.x.1,10.x.x.2]. |
31800 | Managed Fabric Health Restored Alert Notice |
---|---|
Description | Send an alert when the fabric health is changed to Green. |
Preconditions | Fabric is created and devices are added and configured in the fabric. |
Requirements |
Alert shows the following data:
The following example shows an alert when a fabric health is
restored:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.x.x.x” enterpriseId=”1916” software=”XCO” swVersion=”3.3.0”] [alert@1916 resource=”/App/Component/Fabric?fabric_name=fb” alertId=”31800” cause=”fabricHealthRestored” type=”fabricService” severity=”info”] [alertData@1916 fabric_name=”fb” fabric_health_info=”” ] BOM : The fabric “fb” health is restored. |
Health Response |
Response
{ Resource: /App/Component/Fabric?fabric_name=fb HQI { Color: Green Value: 0 } StatusText : The fabric “fb” health is restored. |