Power Specifications

109531095110941XN-ACPWR-2000-F*
Voltage Input Range (Nominal)100VAC-127VAC/

200VAC-240VAC

100VAC-127VAC/

200VAC-240VAC

100VAC-127VAC/

200VAC-240VAC

100VAC-127VAC/

200VAC-240VAC

Line Frequency Range50Hz to 60Hz50Hz to 60Hz50Hz to 60Hz50Hz to 60Hz
Power Supply Input SocketIEC/EN 60320 C14IEC/EN 60320 C16IEC/EN 60320 C16IEC/EN 60320 C16
Power Cord Input PlugIEC/EN 60320 C13IEC/EN 60320 C15IEC/EN 60320 C15IEC/EN 60320 C15
Operating Temperature0°C to 55°C

(32°F to 131°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

0°C to 55°C

(32°F to 131°F)

Normal Operation

Power Supply Specifications (cont.)

XN-ACPWR-350W-FBXN-ACPWR-350W-BFXN-ACPWR-715W-FBXN-ACPWR-1100W-FBXN-ACPWR-2000W-FB*
Voltage Input Range (Nominal)100VAC-240VAC100VAC-240VAC100VAC-240VAC100VAC-240VAC100VAC-240VAC
Line Frequency Range50Hz to 60Hz50Hz to 60Hz50Hz to 60Hz50Hz to 60Hz50Hz to 60Hz
Power Supply Input SocketIEC/EN 60320 C14IEC/EN 60320 C14IEC/EN 60320 C16IEC/EN 60320 C16IEC/EN 60320 C16
Power Cord Input PlugIEC/EN 60320 C13IEC/EN 60320 C13IEC/EN 60320 C15IEC/EN 60320 C15IEC/EN 60320 C15
Operating Temperature0°C to 55°C

(32°F to 131°F)

Normal Operation

0°C to 55°C

(32°F to 131°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

Power Supply Specifications (cont.)

XN-ACPWR-550W-FBXN-ACPWR-550W-BFXN-DCPWR-550W-FBXN-DCPWR-550W-BF
Voltage Input Range (Nominal)100VAC-240VAC100VAC-240VAC-48VDC

(-36VDC to -72VDC)

-48VDC

(-36VDC to -72VDC)

Line Frequency Range50Hz to 60Hz50Hz to 60HzN/AN/A
Power Supply Input SocketIEC 320 - C14IEC 320 - C14POSITRONIC PN#

PLAH03M400A1/AA-E1A

POSITRONIC PN#

PLAH03M400A1/AA-E1A

Power Cord Input PlugIEC 320 - C13IEC 320 - C13POSITRONIC PN#

PLAH03M400A1/AA-E1A

POSITRONIC PN#

PLAH03M400A1/AA-E1A

Operating Temperature0°C to 50°C

(32°F to 122°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

0°C to 50°C

(32°F to 122°F)

Normal Operation

PoE Power Budget

Switch Model1 x 715W2x 715W1 x 1100W2 x 1100W

1 x 2000W @

100-120VAC

1 x 2000W @

200-240VAC

2 x 2000W @

100-120VAC

2 x 2000W @

200-240VAC

5520-24W494W1079W879W1781W879W1779W1869W2160W
5520-48W483W1068W868W1770W868W1768W1858W3568W
5520-12MW-36W464W1049W849W1751W849W1749W1839W3549W

Note: It is recommended that primary and secondary power supply units (PSUs) be of the same type to support optimal PoE operation.

Minimum/Maximum Power Consumption and Heat Dissipation

Switch ModelMinimum Power Consumption (W)Minimum Heat Dissipation (BTU/hr)Maximum Power Consumption (W)*Maximum Heat Dissipation (BTU/hr)**
5520-24T52176142483
5520-24W5418224801092
5520-48T60205171584
5520-48W5920341001817
5520-12MW-36W6622440951862
5520-48SE61209255872
5520-24X48165171585
5520-24T-ACDC41140135459
5520-48T-ACDC46156141481
5520-24X-ACDC39132169575
5520-48SE-ACDC45154223760