Cloning Switches
ExtremeXOS switches provide a script called
clone.py that allows you to clone one switch's setup to another switch in
the following scenarios:
The
clone.py script copies the following:
- All content under:
- /boot
- /exos
- /alt/boot
- /alt/exos
- (optionally) /usr/local/cfg
- Specific NVRAM contents:
- Boot selector
- CLI banner
- Failsafe username,password, and action
Limitations
- Requires ExtremeXOS 30.3 or later.
- Cloning to a standalone switch using a stacking master as the source does not make the
standalone switch a stacking master. The configuration cloned from a stacking master to the
standalone switch is ignored by ExtremeXOS.
- ONIE to non-ONIE or non-ONIE to ONIE
cloning cannot be performed.
Most of the newer ExtremeSwitching series switches (X465, X870, X690, X695 ,
X590) use the Open Network Install Environment (ONIE) bootloader. All other ExtremeSwitching series switches
do not use ONIE.
- Clone application does not connect through VR-USER.
- Synchronize cannot be done for mixed stacking. All nodes in the stack must be the same
platform.
- If the clone master is started and stopped, the dirty bit is set.
Supported Platforms
Cloning is supported on ExtremeSwitching
X435,
X450-G2, X460-G2, X670-G2, X440-G2, X465, X870, X620, X690, X695,
X590, 5320, 5420, 5520 series switches.