Resolved Issues in ExtremeXOS 16.2.5-Patch1-25

The following issues were resolved in ExtremeXOS 16.2.5-Patch1-25. ExtremeXOS 16.2.5-Patch1-25 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, ExtremeXOS 16.2.3, ExtremeXOS 16.2.4, and ExtremeXOS 16.2.5. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 16.2.5-Patch1-25
Defect Number Description
General
EXOS-26124 With SRP configured on VPLS service VMAN, when primary or secondary port goes down, the other port is not passing traffic through the tunnel.
EXOS-24140 Traffic loss occurs when default route is installed with IP route compression enabled.
EXOS-24121 When refreshing policy files, process HAL ends unexpectedly with signal 11.
EXOS-23947 IPv6 ping fails over PSTag.
EXOS-23878 VLAN process ends unexpectedly while doing SNMP polling on EXTREME-VLAN-PORT MIB.
SummitStack
EXOS-24059 On SummitStacks, when port is in software learning mode, FDB is not programmed in hardware on all slots resulting in flooding.
EXOS-24080 Need to add ExtremeXOS support for active monitoring of fan RPM in stack setups.
BlackDiamond 8800 Series Switches
EXOS-26281 DDMI error messages appear after running the "show port transceiver information" command when peer port is disabled, and then enabled.